Mcro 19-XD - Servce & Parts Manual
June 2020
Secton 10 - Mantenance
Lower the platform to the stowed position and turn the machine off.
Tires And Wheels
Maintaining the tires and wheels in good condition is essential to safe operation and good
performance. Tire and/or wheel failure could result in a machine tip-over. Component damage may
also result if problems are not discovered and repaired in a timely fashion.
Check the tire surface and sidewalls for cuts, cracks, punctures and unusual wear.
Check each wheel for damage, bends and cracks.
Remove the wheel covers and check each center lock nut for proper torque and presence of
cotter pin.
Front
Back
Castle Nut Torque, Dry
166.7 ft-Ibs / 226 Nm
Castle Nut Torque, Lubricated
125.4 ft-Ibs / 170 Nm
Locknut
100 ft-Ibs / 135 Nm
Emergency Stop
A properly functioning Emergency Stop system is essential for safe machine operation. An improperly
operating red Emergency Stop button will fail to shut off power and stop all machine functions,
resulting in a hazardous situation.
As a safety feature, selecting and operating from the ground controls will override all platform controls
except the platform red Emergency Stop button.
Turn the key switch to ground control and turn the red Emergency Stop button clockwise to the
on position at both the ground and platform controls.
Push in the red Emergency Stop button at the ground controls to the off position.
Result:
No machine functions should operate.
Turn the key switch to platform control and turn the red Emergency Stop button clockwise to the
on position at both the ground and platform controls.
Push in the red Emergency Stop button at the platform controls to the off position.
Result:
No machine functions should operate.
NOTE: The red Emergency Stop button at the ground controls will stop all machine operation,
even if the key switch is switched to platform control������
Key Switch
Proper key switch action and response is essential to safe machine operation. The machine can be
operated from the ground or platform controls and the activation of one or the other is accomplished
with the key switch. Failure of the key switch to activate the appropriate control panel could cause a
hazardous operating situation.
Perform this procedure from the ground using the platform controls. Do not stand in the platform.
Turn the red Emergency Stop button clockwise to the on position at both the ground and
platform controls.
10.
•
•
•
1.
2.
•
3.
4.
•
1.
Содержание Micro 13-XD
Страница 1: ...Part 43894 June 2020 Service Parts Manual Micro 19 XD Serial Number Range 1610000 Up Art_5588 ...
Страница 38: ...Page 34 Micro 19 XD Service Parts Manual June 2020 Notes ...
Страница 83: ...Page 79 Micro 19 XD Service Parts Manual June 2020 Notes ...
Страница 84: ...Page 80 Micro 19 XD Service Parts Manual June 2020 Notes ...
Страница 85: ...Page 81 Micro 19 XD Service Parts Manual June 2020 Notes ...