Mec ATLAS-650 Series Скачать руководство пользователя страница 2

 

Instruction Manual

 

ATLAS-650 Series

 

Version: May 2020

 

- 2 -

 

Mainland Energy Conversion Ltd.         

Tel:  +

852  2366  9610 

    E-mail

[email protected]

 

           

www.mec-powersolutions.com

 

Models Targeting Lead-based Batteries 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Preparation 

– Before Charging

 

 

General Checking 

 

Check thoroughly the charger itself including all the cables show no damages 

 

Take into consideration the charging instruction issued by the battery manufacturer   

 

Charging Cable – Polarity Checking 

WARNING: Check the polarity before mounting onto a plug: 
 

 

Red cable = Plus (+) 

 

Black cable = Minus (-) 

 
DC Mains Supply Checking 

 

Make sure the DC cable must not be cut, shortened or extended under any circumstances 

 

Make sure the mains supply complies with the technical specification requirements of the charger 

 

Before Connecting the Charger to the Battery 

 

<For models targeting lead-acid batteries> First connect charger to the mains to select the appropriate loader, then disconnect from the 
mains and connect the temperature sensor to the battery (the assembly depends on the battery manufacturer) 
 

 

<For all models> Make sure the charger is switched off and disconnected from the mains supply 

 

Then connect the terminals of the charger to the battery 

 

Finally connect the power cable of the charger to the mains supply, and switch on the charger 

 

The immobilizer core is switched to 0V when the charging process starts 

 

For Models Targeting Lead-based Batteries 
 

 

Select the desired charge profile: 
With proper connection, the LED of the currently active charge profile lights up continuously. To change the charge profile, press and hold the 
"Press Button" for 5 seconds, the LED of the active profile will then change to slow flashing. Now you can switch between the different charge 
profiles by briefly pressing the "Press Button". When the desired profile is selected, confirm the selection by pressing the "Press Button” again 
for 5 seconds, the LED of the selected charge profile changes to steady lighting. 

 

 

Select the Power Supply Mode: 
Follow the steps above to select a charge profile; the Power Supply Mode is signaled by the lighting up of all the 4 charge profile LEDs. 

 

 

The latest selected charge profile will be kept unless you change it 
 

Charging the Battery

 

 
The charging process starts automatically and runs through the following stages: 
 

Getting Ready: Auto Wake-up 

Yellow Charge LED (4) and Green Full LED (3) are blinking alternately. During this pre-charge phase, the charger sends  out series of controlled 
current pulses to reactivate the BMS (if any) and bring in a voltage to the battery for getting ready for the charging process. If no battery or defected 
battery pack is connected, the Red Error LED blinks. In this case, switch off the charger and check the battery pack. 
 
 
 

1. 

Selection Switch 

2. 

Program LED 

3. 

Green Full LED 

4. 

Yellow Charge LED 

5. 

Green Mains LED 

6. 

Red Error LED 

7. 

IR-Interface LEDs 

8. 

DC Cable (Red + ; Black - ) 

9. 

Temperature Sensor 

10.  Ignition Lock (model dependent) 

11.  Display Terminal (model dependent) 

12.  AC Cable 

Отзывы: