Preparation 

– Before Charging

 

 

General Checking 

 

Check thoroughly the charger itself including all the cables show no damages 

 

Take into consideration the charging instruction issued by the battery manufacturer   

 

Charging Cable – Polarity Checking 

WARNING: Check the polarity before mounting onto a plug: 
 

 

Red cable = Plus (+) 

 

Black cable = Minus (-) 

 
DC Mains Supply Checking 

 

Make sure the DC cable must not be cut, shortened or extended under any circumstances 

 

Make sure the mains supply complies with the technical specification requirements of the charger 

 

Before Connecting the Charger to the Battery 

 

<For models targeting lead-acid batteries> First connect charger to the mains to select the appropriate loader, then disconnect from the 
mains and connect the temperature sensor to the battery (the assembly depends on the battery manufacturer) 
 

 

<For all models> Make sure the charger is switched off and disconnected from the mains supply 

 

Then connect the terminals of the charger to the battery 

 

Finally connect the power cable of the charger to the mains supply, and switch on the charger 

 

The immobilizer core is switched to 0V when the charging process starts 

 

For Models Targeting Lead-based Batteries 
 

 

Select the desired charge profile: 
With proper connection, the LED of the currently active charge profile lights up continuously. To change the charge profile, press and hold the 
"Press Button" for 5 seconds, the LED of the active profile will then change to slow flashing. Now you can switch between the different charge 
profiles by briefly pressing the "Press Button". When the desired profile is selected, confirm the selection by pressing the "Press Button” again 
for 5 seconds, the LED of the selected charge profile changes to steady lighting. 

 

 

Select the Power Supply Mode: 
Follow the steps above to select a charge profile; the Power Supply Mode is signaled by the lighting up of all the 4 charge profile LEDs. 

 

 

The latest selected charge profile will be kept unless you change it 
 
 

Charging the Battery

 

 
The charging process starts automatically and runs through the following stages: 
 

Getting Ready: Auto Wake-up 

Yellow Charge LED (6) and Green Full LED (7) are blinking alternately. During this pre-charge phase, the charger sends  out series of controlled 
current pulses to reactivate the BMS (if any) and bring in a voltage to the battery for getting ready for the charging process. If no battery or defected 
battery pack is connected, the Red Error LED blinks. In this case, switch off the charger and check the battery pack. 
 

Phase 1: Soft Start 

Yellow Charge LED (6) keeps on lighting. The charger regulates the initial charging current to better prolong the battery life. 
 

Phase 2: Constant Current Charging 

Yellow Charge LED (6) blinks slowly. The battery is being charged to 80% of its capacity at this stage. 
 

Phase 3: Constant Voltage Charging 

Yellow Charge LED (6) blinks quickly. The battery is being charged to its maximum capacity. When the Green Full LED (7) turns on, the charger can 
now be disconnected from the battery. 
 

Phase 4: Float Charging (for lead-based batteries only) or Auto Restart 

Green Full LED (7) keeps on lighting indicate the battery has reached its full capacity. If the battery keeps connecting to the charger, auto restart of 
the charging cycle will take place after 7 days or when the battery voltage  has dropped to under 3.6V/cell (Li-ion Battery) or 3.2V/cell (LiFePO4 
Battery). 

 
Disconnect the Charger from the Battery: 

 
1. 

First, disconnect the charger from the mains supply 

2. 

Then, disconnect the charger from the battery 

 
After disconnecting the charger from the mains, please wait at least 5 seconds  to reactivate the charger if in need – otherwise damages may be 