Measurement Computing USB-234 Скачать руководство пользователя страница 28

 

 

Declaration of Conformity 

Manufacturer: 

Measurement Computing Corporation 

Address: 

10 Commerce Way 

 

Suite 1008 

 

Norton, MA  02766 

 

USA 

Category: 

Electrical equipment for measurement, control and laboratory use. 

 
Date of Issue: 

June 27, 2014 

Measurement Computing Corporation declares under sole responsibility that the product 

 

USB-234 

to which this declaration relates is in conformity with the relevant provisions of the following standards or other 
documents: 

EC EMC Directive 2004/108/EC: General Requirements, EN 61326-1:2006 (IEC 61326-1:2005).  

Emissions:  

 

EN 55011 (2010) / CISPR 11(2010): Radiated emissions: Group 1, Class A  

 

EN 55011 (2010) / CISPR 11(2010): Conducted emissions: Group 1, Class A 

Immunity:  EN 61326-1:2006, Table 1.  

 

IEC 61000-4-2 (2001): Electrostatic Discharge immunity. 

 

IEC 61000-4-3 (2002): Radiated Electromagnetic Field immunity. 

 

IEC 61000-4-4 (2004): Electric Fast Transient Burst Immunity. 

 

IEC 61000-4-5 (2001): Surge Immunity. 

 

IEC 61000-4-6 (2007): Radio Frequency Common Mode Immunity. 

 

IEC 61000-4-11 (2004): Voltage Interruptions. 

To maintain compliance to the standards of this declaration, the following conditions must be met. 

 

The host computer, peripheral equipment, power sources, and expansion hardware must be CE compliant. 

 

All I/O cables must be shielded, with the shields connected to ground. 

 

I/O cables must be less than 0.5 meter (20 in.) in length. 

 

The host computer must be properly grounded. 

Declaration of Conformity based on tests conducted by National Instruments Corporation, 11500

 

North MoPac 

Expressway, Austin, Texas 78759, USA in March, 2014. Test records are outlined in National Instruments Test 
Report #20140610-1451-SF.  

We hereby declare that the equipment specified conforms to the above Directives and Standards. 

 

 

Carl Haapaoja, Director of Quality Assurance 

 

 

Содержание USB-234

Страница 1: ...USB 234 Analog and Digital I O User s Guide Document Revision 3 October 2017 Copyright 2017...

Страница 2: ...in any form by any means electronic mechanical by photocopying recording or otherwise without the prior written permission of Measurement Computing Corporation Notice Measurement Computing Corporation...

Страница 3: ...Calibrating the hardware 9 Chapter 3 Functional Details 10 Analog input acquisition modes 10 Software paced mode 10 Hardware paced mode 10 External components 11 Screw terminals 11 USB connector 13 LE...

Страница 4: ...er requirements 25 Power output 25 USB specifications 25 Environmental 26 Mechanical 26 Screw terminal connector 26 Screw terminal pinout 27 Differential mode pinout 27 Single ended mode pinout 27 Dec...

Страница 5: ...ging your hardware or losing your data bold text Bold text is used for the names of objects on a screen such as buttons text boxes and check boxes italic text Italic text is used for the names of manu...

Страница 6: ...ccur when the USB 234 is connected through USB 1 1 ports or hubs Device features The USB 234 provides the following features Eight single ended SE or four differential DIFF 16 bit analog inputs 100 kS...

Страница 7: ...USB 234 User s Guide Introducing the USB 234 7 Functional block diagram Device functions are illustrated in the block diagram shown here Figure 1 USB 234 functional block diagram...

Страница 8: ...aq com Phone 508 946 5100 and follow the instructions for reaching Tech Support Fax 508 946 9500 to the attention of Tech Support Email techsupport mccdaq com For international customers contact your...

Страница 9: ...blinks If the LED turns off the device is either not fully connected or is in suspend mode If the LED blinks the device has encountered an error Wait 10 seconds to allow the device to attempt to reco...

Страница 10: ...mode You can acquire data from up to eight channels in hardware paced mode The analog data is continuously acquired and converted to digital values until you stop the scan Data is transferred in block...

Страница 11: ...nals provide the following connections refer to Figure 4 and Figure 5 for pinout diagrams Eight single ended four differential analog inputs CH0H CH0L to CH3H CH3L Two analog outputs AOUT0 and AOUT1 D...

Страница 12: ...USB 234 User s Guide Functional Details 12 Figure 4 USB 234 differential pinout...

Страница 13: ...in suspend mode On not blinking Device is connected and functioning normally Blinking Device has encountered an error 1 Wait 10 seconds to allow the device to attempt to recover from the error 2 If t...

Страница 14: ...FO The DAQ device can perform both single and multiple analog to digital conversions of a fixed or infinite number of samples A first in first out FIFO buffer holds data during AI acquisitions to ensu...

Страница 15: ...V Figure 7 Analog input exceeding 10 V returning clipped results Multichannel scanning The USB 234 can scan multiple channels at high rates and digitize the signals accurately However you should consi...

Страница 16: ...signal to the 10 V range and ensures the driving capability for the external load DAC 0 and DAC 1 The digital to analog converters DAC convert the digital signals into low level analog signals AO FIFO...

Страница 17: ...arate command to the hardware to initiate each DAQ conversion Software paced generations are also referred to as immediate or static operations They are typically used for writing a single value out s...

Страница 18: ...ing is not liable for any damage resulting from such signal connections Power on states At system startup and reset the USB 234 sets all DIO lines to high impedance inputs The device does not drive th...

Страница 19: ...re 11 VO power source circuitry The main blocks featured in the VO power source circuitry are as follows 5 V Source Regulated 5 V supply 5 V Protection Circuit for overvoltage over current and short c...

Страница 20: ...vice is first connected to the USB connector or when the device is in suspend mode Ground The analog ground AGND terminals provide a common ground for all analog channels The digital ground DND termin...

Страница 21: ...USB 234 User s Guide Functional Details 21 Mechanical drawings Figure 13 Circuit board top and housing dimensions...

Страница 22: ...100 kS s Number of channels 8 single ended or 4 differential software selectable Input voltage range 10 V Working voltage 10 V Overvoltage protection Power on 30 V max Power off 20 V max Input impedan...

Страница 23: ...full scale 32 mV INL 4 LSB DNL 16 bits no missing codes Power on state 0 V Startup glitch 7 V for 10 s Timebase The following specifications apply to hardware paced analog input and analog output sam...

Страница 24: ...put Table 6 Digital output specifications Parameter Condition Specification Output low voltage 4 mA 0 7 V max 1 mA 0 2 V max Output high voltage 4 mA 2 1 V min 1 mA 2 8 V min 3 6 V max Maximum output...

Страница 25: ...The USB 234 does not work on a bus powered hub Note 3 The maximum power draw from all output terminals should be kept under 0 9 W to avoid overloading the USB port Power output Table 10 External volta...

Страница 26: ...ical Table 13 Mechanical specifications Parameter Conditions Specification Dimensions L W H With screw terminal connector plugs 93 2 86 2 23 6 mm 3 67 3 40 0 93 in Without screw terminals 75 4 86 2 23...

Страница 27: ...14 AOUT0 Analog output 0 30 GND Digital ground 15 AOUT1 Analog output 1 31 VO User voltage output 16 AGND Analog ground 32 GND Digital ground Single ended mode pinout Do not connect to terminal block...

Страница 28: ...2002 Radiated Electromagnetic Field immunity IEC 61000 4 4 2004 Electric Fast Transient Burst Immunity IEC 61000 4 5 2001 Surge Immunity IEC 61000 4 6 2007 Radio Frequency Common Mode Immunity IEC 610...

Страница 29: ...Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton Massachusetts 02766 508 946 5100 Fax 508 946 9500 E mail info mccdaq com www mccdaq com...

Отзывы: