background image

PMD-1024HLS User's Guide 

Specifications 

General 

Table 4-4. General specifications  

Parameter Conditions 

Specification 

25 °C 

±30 ppm max 

USB controller clock error 

0 to 70 °C 

±50 ppm max 

Device type 

 

USB 1.1 low-speed 

Device compatibility 

 

USB 1.1, USB 2.0 

Environmental 

Table 4-5. Environmental specifications  

Operating temperature range

 

0 to 70

 

°C

 

Storage temperature range

 

-40 to 85 °C

 

Humidity

 

0 to 90% non-condensing

 

Mechanical 

Table 4-6. Mechanical specifications  

Dimensions 

79 mm (L) x 82 mm (W) x 25 mm (H)  

USB cable Length 

2 meters max 

USB cable type 

A-B cable, UL type AWM 2527 or equivalent. (min 24 AWG VBUS/GND,  
min 28 AWG D+/D-) 

User connection length 

3 meters max 

Main connector and pin out  

Table 4-7. Connector specifications  

Connector type 

Screw terminal 

Wire gauge range 

30-16 AWG 

Table 4-8. Connector pin out  

Pin 

Signal Name 

Pin 

Signal Name 

Port C0 

21 

Port A0 

Port C1 

22 

Port A1 

Port C2 

23 

Port A2 

Port C3 

24 

Port A3 

Port C4 

25 

Port A4 

Port C5 

26 

Port A5 

Port C6 

27 

Port A6 

Port C7 

28 

Port A7 

9 GND 

29 

GND 

10 

USB +5 V 

30 

USB +5 V 

11 

Port C Pull-up / Pull-down 

31 

GND 

12 GND 

32 

Port 

B0 

13 

Port B Pull-up / Pull-down 

33 

Port B1 

14 

USB +5 V 

34 

Port B2 

15 

Port A Pull-up / Pull-down 

35 

Port B3 

16 GND 

36 

Port 

B4 

17 GND 

37 

Port 

B5 

18 GND 

38 

Port 

B6 

19 GND 

39 

Port 

B7 

20 CTR 

40 

GND 

4-3 

Содержание PMD-1024HLS

Страница 1: ......

Страница 2: ...PMD 1024HLS Personal Measurement Device brand USB based Digital I O Module User s Guide Document Revision 4 May 2005 Copyright 2005 Measurement Computing Corporation ...

Страница 3: ...on that is damaged even due to misuse for only 50 of the current list price I O boards face some tough operating conditions some more severe than the boards are designed to withstand When a board becomes damaged just return the unit with an order for its replacement at only 50 of the current list price We don t need to profit from your misfortune By the way we honor this warranty for any manufactu...

Страница 4: ...use No license is granted by implication or otherwise under any patent or copyrights of Measurement Computing Corporation All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form by any means electronic mechanical by photocopying recording or otherwise without the prior written permission of Measurement Computing Corporation Notice M...

Страница 5: ...Hardware 2 1 Software 2 1 Documentation 2 2 Unpacking the PMD 1024HLS 2 2 Installing the software 2 2 Installing the hardware 2 2 Chapter 3 Functional Details 3 1 External components 3 1 USB connector 3 1 LED 3 1 Screw terminal wiring 3 2 Main connector and pin out 3 2 Digital I O terminals Port A0 to A7 Port B0 to B7 Port C0 to C7 3 3 Power terminals 3 4 Ground terminals 3 5 Counter terminal 3 5 ...

Страница 6: ...names of manuals and help topic titles and to emphasize a word or phrase For example The InstaCal installation procedure is explained in the DAQ Software Quick Start Never touch the exposed pins or circuit connections on the board Where to find more information The following electronic documents provide information that can help you get the most out of your Personal Measurement Device brand PMD 10...

Страница 7: ...e you are using the latest system software note in Chapter to make sure you are using the latest USB drivers 2 Installing the PMD 1024HLS The PMD 1024HLS is a high drive 24 line digital I O module that includes one 32 bit external event counter The PMD 1024HLS is powered by the 5 volt USB supply from your computer No external power is required An emulation of the 82C55 in mode 0 only sets the dire...

Страница 8: ...erminal I O connector 4 4 8 8 8 8 8 1 Figure 1 2 PMD 1024HLS functional block diagram Software features The following software ships with the PMD 1024HLS free of charge InstaCal installation calibration and test utility TracerDAQ suite of virtual instruments SoftWIRE for Visual Studio NET graphical programming MCC DAQ Components for VS NET installed with SoftWIRE for VS NET For information on the ...

Страница 9: ... DIP switches to set or interrupts to configure You can connect the PMD 1024HLS before or after you install the software and without powering down your computer first When you connect an HID to your system your computer automatically detects it and configures the necessary software You can connect and power multiple HID peripherals to your system using a USB hub You can connect your system to vari...

Страница 10: ...he following components are included Hardware PMD 1024HLS USB cable 2 meter length Software The Measurement Computing Data Acquisition Software CD contains the following software InstaCal installation calibration and test utility TracerDAQ suite of virtual instruments SoftWIRE for VS NET SoftWIRE MCC DAQ Components for NET 2 1 ...

Страница 11: ...ftware Quick Start for instructions on installing the software on the Measurement Computing Data Acquisition Software CD This booklet is available in PDF at www mccdaq com PDFmanuals DAQ Software Quick Start pdf Installing the hardware Be sure you are using the latest system software Before you connect the PMD 1024HLS make sure that you are using the latest versions of the USB drivers Before insta...

Страница 12: ...24HLS should flash and then remain lit This indicates that communication is established between the PMD 1024HLS and your computer Caution Do not disconnect any device from the USB bus while the computer is communicating with the PMD 1024HLS or you may lose data and or your ability to communicate with the PMD 1024HLS If the LED turns off If the LED is lit but then turns off the computer has lost co...

Страница 13: ...wer and communication The voltage output is system dependent and may be less than 5 V No external power supply is required LED The LED on the front of the housing indicates the communication status of the PMD 1024HLS It uses up to 5 mA of current and cannot be disabled explains the function of the PMD 1024HLS LED Table 3 1 Table 3 1 LED illumination LED Illumination Indication Steady green The PMD...

Страница 14: ...nections Eight digital I O connections Port C0 to Port C7 One counter connection CTR Two power connections USB 5 V Three pull up and pull down connections Port A Pull up Pull down Port B Pull up Pull down and Port C Pull up Pull down Six ground connections GND Screw terminal pins 21 40 The screw terminals on the bottom edge of the PMD 1024HLS pins 21 to 40 provide the following connections 16 digi...

Страница 15: ...o A7 Port B0 to B7 Port C0 to C7 Connect up to 24 digital I O lines to the screw terminal containing pins 1 to 8 Port C0 to Port C7 pins 21 to 28 Port A0 to Port A7 and pins 32 to 39 Port B0 to Port B7 Refer to the pinout diagram on page 3 2 for the location of these pins You can configure each digital port for either input or output When configured for input you can use the PMD 1024HLS digital I ...

Страница 16: ...d on the application and the allowed current draw of the computer platform The following power limits depend on whether you are sourcing current out of the PMD 1024HLS or you are sinking current into the PMD 1024HLS Output source current limits desktop computers and self powered hubs The maximum allowed current draw for a typical desktop computer and self powered hub is 500 mA For an application r...

Страница 17: ...Refer to the pinout diagram on page 3 2 for the location of this terminal The internal counter increments when the TTL levels transition from low to high The counter can count frequencies of up to 1 MHz Pull up pull down terminals You can wire pin 11 Port C Pull up Pull down pin 13 Port B Pull up Pull down and pin 15 Port A Pull up Pull down to support a pull up or pull down connection These termi...

Страница 18: ...iring options Figure 3 8 Schematic showing Port B pull up pull down wiring options Figure 3 9 Schematic showing Port C pull up pull down wiring options USB 5 V GND DIO 7 Port C7 DIO 6 Port C 6 DIO 5 Port C5 DIO 4 Port C4 DIO 3 Port C3 DIO 2 Port C2 DIO 1 Port C1 DIO 0 Port C0 Port C Pin 11 Pull up Pull down GND DIO 7 Port A7 DIO 6 Port A6 DIO 5 Port A5 DIO 4 Port A4 DIO 3 Port A3 DIO 2 Port A2 DIO...

Страница 19: ...are root port hubs All externally powered root port hubs i e desktop PC s provide up to 500 mA of current for a USB device In this configuration all 24 digital outputs of the PMD 1024HLS can source their per pin maximum of 15 mA This provides a total requirement of 15 mA 24 360 mA Combining this with the PMD 1024HLS operating current of 60 mA a fully loaded current draw of 420 mA is realized Bus p...

Страница 20: ...terminals pins 10 14 and 30 4 4 V min 5 25 V max Connected to Self powered hub Externally powered root port hub 350 mA total output source current USB 5 V power output current Note 7 Connected to Bus powered hub Battery powered root port hub 60 mA total output source current Hold current 350 mA typical Trip current 700 mA typical Trip recovery time 100 mS max USB 5 V overcurrent protection Resetta...

Страница 21: ...e A B cable UL type AWM 2527 or equivalent min 24 AWG VBUS GND min 28 AWG D D User connection length 3 meters max Main connector and pin out Table 4 7 Connector specifications Connector type Screw terminal Wire gauge range 30 16 AWG Table 4 8 Connector pin out Pin Signal Name Pin Signal Name 1 Port C0 21 Port A0 2 Port C1 22 Port A1 3 Port C2 23 Port A2 4 Port C3 24 Port A3 5 Port C4 25 Port A4 6 ...

Страница 22: ... 11 Radiated and Conducted emissions Immunity EN61326 Annex A EN 61000 4 2 1995 Electrostatic Discharge immunity Criteria C EN 61000 4 3 1997 Radiated Electromagnetic Field immunity Criteria A EN 61000 4 8 1995 Power Frequency Magnetic Field immunity Criteria A Power line and I O tests to EN61000 4 4 EN61000 4 5 EN61000 4 6 and EN61000 4 11 were not required The device is DC powered from an I O ca...

Страница 23: ...Measurement Computing Corporation 16 Commerce Boulevard Middleboro Massachusetts 02346 508 946 5100 Fax 508 946 9500 E mail info mccdaq com www mccdaq com ...

Отзывы: