background image

3.6

Short Circuit Protection & Over Current Protection

3.7

Over Voltage Protection (OVP)

3.8

Over Temperature Protection (OTP) and Alarm

The protection activates when the output is short-circuited or the output current exceeds 110%±5 of the rated output current.

.

Built-in over voltage protection circuit

Built-in thermal detection circuit, once the internal temperature exceeds a threshold value, the unit will shut down automatically.

When the internal temperature is within a normal value, there will be a LOW signal (-0.5-0.5V) sent out through T-ALARM on

"

"

Maximum output current: 10mA

When internal temperature reaches 85

, trigger point of a thermal alarm, the red LED on the output will flash and there will be an

alarm signal sent out through the PMBus/CANBus (by request) interface, please refer to 3.13.2. Even so, the unit is still operating

normally.

.

OVP triggering points vary in different output models. Please refer to the specification sheet for detailed information

Once OVP is triggered, leave the unit off for 20 seconds before recycling AC again.

Re-power on to recover when short-circuit/overload condition is removed.

Please switch off the AC input, remove all possible causes and then leave the unit cooling down to a normal working temperature

(approximate  10 minutes - 1 hour) before repower on again.

CN47; There will be a HIGH signal (3.5-5.5V) sent out through T-ALARM on CN47 when internal temperature exceeds a

"

"

certain value. (referenced to GND-AUX).

6

3.10

Remote Control

Built-in remote ON/OFF control circuit, refer to Figure 3-3 for the control method.

Please be aware that ON/OFF and +12V-AUX

on CN47 should be linked together to allow the unit operate normally; If they

"

"

"

"

are kept open, there will be no output voltage.

Maximum input voltage: 13.2V

Figure 3-3  Connection of Remote Control

Between CN1 ON/OFF and +12V-AUX

SW Open

SW Short

Output

OFF

ON

When DC output voltage is out of normal range, there is a HIGH signal (3.5-5.5V) sent out through DC-OK on CN47.

"

"

Maximum output current: 10mA

When DC output voltage is within a normal value, there is a LOW signal (-0.5-0.5V)sent out through DC-OK on CN47.

"

"

(referenced to GND-AUX)

.

(referenced to GND-AUX)

.

.

Built-in DC output voltage detection circuit

3.9

DC OK Signal

+12V-AUX

CN47

ON/OFF

PHP-3500

3

1

3.11

Parallel Operation

.

Parallel operation is only suitable for the identical units (with the same model and the same output voltage/current)

.

The power supplies should be paralleled using short and large diameter wiring and then connected to the load

The total output current must not exceed the value determined by the following equation: Maximum output current at parallel

operation = (Rated current per unit)x(Number of unit)x0.9.

the current shared among units may not be balanced.

normal ripple level once the output load is more than 5%.

When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)x(Number of unit)

Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition, It will go back to

.

CN55/SW51 Function pin connection

(V : CN55 connected ; X : CN55 not connected.)

Parallel

CN55

CN55

CN55

CN55

SW51

SW51

SW51

SW51

PSU1

PSU2

PSU3

PSU4

1 unit

X

OFF

OFF

OFF

ON

ON

ON

ON

ON

V

V

V

V

ON

V

ON

V

V

V

V

2 unit

3 unit

4 unit

Содержание PHP-3500

Страница 1: ...PHP 3500 User s Manual...

Страница 2: ...Input Voltage Range 3 2 Inrush Current Limiting 4 2 Derating 4 1 Installation Method 3 3 Rated Power 3 4 Power Factor Correction PFC 3 5 Output Voltage Current Adjustment 3 6 Short Circuit and Over Cu...

Страница 3: ...al AC input Full range Built in active PFC function PF 0 95 Protection Short circuit Overload Over voltage Over temperature Built in remote ON OFF control Output voltage programming Output current pro...

Страница 4: ...uidance on how to perform these EMC tests please refer to EMI testing of component power supplies as available on http www meanwell com 9 The ambient temperature derating of 3 5 1000m with fanless mod...

Страница 5: ...erload protection Fan fail Red Flashing The LED will flash with red light when internal temperature reaches under this condition the unit still operates normally without entering 85 OT In the meantime...

Страница 6: ...terface Note 2 For CANBus model Data line used in CANBus interface Note 2 SDA CANH 17 18 The signal return is isolated from the output terminals V V GND AUX S Connection for constant current level pro...

Страница 7: ...Figure 3 1 Connection of external DC voltage source PV 5 6 1 0 5V V Figure 3 2 Note The PHP 3500 will trigger OLP to shut down itself if the output stays at constant current level condition for more t...

Страница 8: ...e 3 3 for the control method Please be aware that ON OFF and 12V AUX on CN47 should be linked together to allow the unit operate normally If they are kept open there will be no output voltage Maximum...

Страница 9: ...gned When DIP switch in the ON position means logic 0 when it is in the OFF position meaning logic 1 for example position 3 in OFF the corresponding bit A2 is set to logic 1 Please refer to Table 3 1...

Страница 10: ...ommands 01h 22h and 46h are saved into EEPROM and take effect after the digital 3 1 3 5 PMBus Command List The command list of the PHP 3500 is shown in Table3 2 It is compliant with the standard proto...

Страница 11: ...1 The PFC activate 1 Active dummy load activate 1 The unit in an initial state Note Unsupported settings display with 0 0b10 Power on with the last setting 0b11 Not used Note Unsupported settings dis...

Страница 12: ...rent Model Model 24V 24V 12 28 8V 48V 48V 24 57 6V Table 3 6 Table 3 5 Note 2 When using PMBus to adjust output voltage VOUT_COMMAND only can be used to display the rated voltage of the unit and 4 Dat...

Страница 13: ...nteger IRECT format data may be used with any command that sends or reads a arametric value If a PMBus device uses DIRECT form data this shall be clearly described in the product literature The host s...

Страница 14: ...AC input voltage the unit will derate its output current automatically to protect itself shown as Figure 4 2 12 LOAD INPUT VOLTAGE VAC 60Hz 90 100 115 180 264 100 50 12AWG UL1015 12AWG UL1015 50mm 22...

Страница 15: ...o avoid condensation please follow below Flatness between mating parts plays a critical role in thermal contact conductance Please make sure cooling capacity of the chiller is greater than 175W so as...

Страница 16: ...Ordering No HS 656 4 5 Warranty A five year global warranty is provided under normal operation Please do not change any component or modify the unit by yourself or MEANWELL may reserve the right not...

Страница 17: ...No 28 Wuquan 3rd Rd Wugu Dist New Taipei City 248 Taiwan...