Mean Well DDR-480B-12 Скачать руководство пользователя страница 4

                           

Installation Manual

 

 

3

1

2

4

e

Shake the unit slightly to check the locking action. 

 
 
 
 
 
 
 
 
 
 

10

For other information about the products, please refer to www.meanwell.com for details. 

 

 

Warning / Caution !! 

1

Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do 

not remove the case of the power supply by yourself! 

2

Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides 

together is not allowed. 

3

Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection! 

4

Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids. 

5

Only install the unit in a pollution degree 2 environment (Note.1).

 

6

Please do not install the unit in places with high moisture or near the water. 

7

The maximum operating temperature is 55°C for DDR-120 series , 50°C for DDR-240 series and 60°C for 

DDR-480 series. Please do not install the unit in places with high ambient temperature or near fire source. 

8

The FG (

     

) must be connected to PE (Protective Earth). 

9

Output current and output wattage must not exceed the rated value on its specification. 

10

Disconnect system from supply voltage:

 

Before commencing any installation, maintenance or modification work: Disconnect your system from 
supply voltage. Make sure that inadvertent connection in circuit will be impossible! 

11

For continued protection against risk of fire, replace only with same type and rating of fuse. 

Pour ne pas compromettre la protection contre les risqué d’incendie, remplacer par un fusible de même 
type et de memes caractéristiques nominales. 

 

Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become 

conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as 
control cabinets. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

"Click" 

Содержание DDR-480B-12

Страница 1: ...67 2Vin DDR 120D 12 INPUT 67 2 154VDC 2 5A OUTPUT 12V 9A 67 2 86 4Vin 12V 10A 86 4 154Vin DDR 120D 24 INPUT 67 2 154VDC 2 5A OUTPUT 24V 4 5A 67 2 86 4Vin 24V 5A 86 4 154Vin DDR 120D 48 INPUT 67 2 154VDC 2 5A OUTPUT 48V 2 3A 67 2 86 4Vin 48V 2 5A 86 4 154Vin DDR 240B 24 INPUT 16 8 33 6VDC 13 5A OUTPUT 24V 8A 16 8 21 6Vin 24V 10A 21 6 33 6Vin DDR 240B 48 INPUT 16 8 33 6VDC 13 5A OUTPUT 48V 4A 16 8 2...

Страница 2: ...wide operating temperature 40 80 for DDR 480 series 4kVdc I O isolation 150 peak load current sharing DC OK adjustable output voltage and full protective functions This series of models has various input options 9 18V 16 8 33 6V 33 6 67 2V 67 2 154V and various output options 12V 24V 48V and can be used for industrial railway control security control communication system and other fields Suitable ...

Страница 3: ... temperatures of at least 80 C such as UL1007 5 Recommended wire strapping length is 5mm 0 197 6 Recommended screwdriver is 4mm slotted type 7 The recommended torque setting for terminals is shown as below Model I P O P DDR 120 6 9 kgf cm 6 Lb in 6 9 kgf cm 6 Lb in DDR 240 8 06 kgf cm 7 Lb in 5 13 kgf cm 4 45 Lb in DDR 480 10 3 kgf cm 9 Lb in 8 06 kgf cm 7 Lb in 8 Suggested fuse is shown as below ...

Страница 4: ...he maximum operating temperature is 55 C for DDR 120 series 50 C for DDR 240 series and 60 C for DDR 480 series Please do not install the unit in places with high ambient temperature or near fire source 8 The FG must be connected to PE Protective Earth 9 Output current and output wattage must not exceed the rated value on its specification 10 Disconnect system from supply voltage Before commencing...

Страница 5: ...ELL GUANGZHOU ENTERPRISES Co LTD No 11 Jingu South Road Huadong Town Huadu Distric Guangzhou Gungzhou China Tel 86 20 3773 7100 Web www meanwell com cn China SUZHOU MEAN WELL TECHNOLOGY Co LTD No 77 Jian Ming Rd Dong Qiao Pan Yang lnd Park Huang Dai Town Xiang Cheng District Suzhou Jiang Su China Post Code 215152 Tel 86 512 6508 8600 Web www meanwell cc U S A MEAN WELL USA INC 44030 Fremont Blvd F...

Страница 6: ...roducts Appendix B adopting table look up to verify the Environment Friendly Use Period Names and Contents of Hazardous Substances Lists Part Name Hazardous Substances Lead Pb Mercury Hg Cadmium Cd Hexavalent chromium Cr6 Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PCB and its components X O X O O O Metal structure parts X O O O O O Plastic structure parts O O O O O O Accessor...

Страница 7: ... to China s Standardization Administration Releases VOC Standards Standard No Name of the Standard GB 30981 2020 Limit of harmful substances of industrial protective coatings GB 33372 2020 Limits for volatile organic compounds content in adhesive GB 38507 2020 Limits for volatile organic compounds VOCs In printing ink GB 38508 2020 Limits for volatile organic compounds content in cleaning agents ...

Страница 8: ...reby confirms that MEAN WELL product series comply with Use and Risk Management for Five PBT Chemicals under TSCA section 6 h CAS No Substance Name 1163 19 5 Decabromodiphenyl ether DecaBDE 68937 41 7 Phenol isopropylated phosphate 3 1 PIP 3 1 732 26 3 2 4 6 Tris tert butyl phenol 2 4 6 TTBP 133 49 3 Pentachlorothiophenol PCTP 87 68 3 Hexachlorobutadiene HCBD ...

Отзывы: