Communications between the main unit (receiver) and the remote sensor (transmitter) is 
wireless. This allows you to greater flexibility in choosing the location of remote sensor. The 
remote transmits data up to 164 feet (50 meters) over an open, unobstructed area.

The remote sensor can be located either indoors or outdoors, allowing you chose where your 
data is obtained.

NOTE:

• It is critical to power the remote sensor 

BEFORE

 setting up the main unit.

• It is critical to power up and 

test

 communication between the remote sensor and the main unit 

BEFORE

 permanently mounting outside.

BEFORE YOU BEGIN

• We recommend using 

alkaline batteries

 for the remote sensor and the main unit. If outdoor 

  temperatures regularly fall 

below 32°F

 (0°C), we recommend using 

lithium

 batteries.

• Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power 
  requirements.)

ALWAYS

 insert batteries into the 

remote

 sensor 

before

 the main unit.

• Insert batteries before first use, matching the polarity in the battery compartment.

• During initial set up, place the remote sensor close to the main unit. 

• After reception is established (remote readings will be appeared on the main unit’s display), 
  position the remote sensor and the main unit within the effective transmission range of up to 
  164 feet (50 meters).

• The main unit must be placed indoors.

NOTE:

• Avoid pressing any buttons on the main unit before the remote readings are displayed.

• Transmission or reception range may be affected by trees, metal structures, and electronic 
  appliances, surrounding building materials and how the main unit and transmitter are 
  positioned.

• Place the remote sensor so that it faces the main unit (receiver), minimizing obstructions such 
  as doors, walls and furniture.

• Though the remote sensors are weather-resistant, they should be placed away from direct 
  sunlight, rain or snow. The optimal location for the remote sensor outdoors is under the eaves 
  on the north side of the building.

3

Содержание TE256W

Страница 1: ...TE256W Slim Indoor Outdoor Thermo Hygrometer with Atomic Clock USER MANUAL...

Страница 2: ...rs famous for its innovative high performance telescopes at affordable prices Meade Instruments now brings that same passion for innovation and high performance to its own line of precision feature ri...

Страница 3: ...LWAYS insert batteries into the remote sensor before the main unit Insert batteries before first use matching the polarity in the battery compartment During initial set up place the remote sensor clos...

Страница 4: ...lt in reduced the transmission range For optimum performance in cold weather conditions we recommend using lithium batteries NOTE Install the batteries before mounting the remote sensor Remove the scr...

Страница 5: ...are installed the remote sensor will start transmitting a temperature and humidity data to the main unit MAIN UNIT FEATURES TIME Precise time and date set via signals from the US Atomic clock 12 or 2...

Страница 6: ...FRONT REAR J K L A C B F E D H I G 6...

Страница 7: ...s F MODE button When time mode has been selected press once to toggle between time with seconds display or time with weekday display Press and hold for 2 seconds set language of the day of the week ye...

Страница 8: ...nit supports up to 3 remote sensors corresponding to a separate channel of the temperature and relative humidity display The temperature can be displayed in Celsius C or Fahrenheit F The main unit car...

Страница 9: ...emperature digits using the UP or DOWN Press and hold either button for fast digits advance Press the ALARM to confirm selection and return to the temperature alarm selection screen ACTIVATING OR DEAC...

Страница 10: ...Make sure the unit is positioned at 8 feet 2 meters distance from any interference source such as a TV computer monitor microwave etc Within concrete wall rooms such as basements or office buildings...

Страница 11: ...SINGLE DAY S ALARMS Press ALARM button once to enter into the alarms setting mode The default alarm is a Weekday alarm W The abbreviation OFF with a letter W next to it will be displayed if the alarm...

Страница 12: ...plastic parts and corrode the electronic circuits Do not subject the product to excessive force shock dust temperature or humidity which may result in malfunctions shorter lifespan damaged batteries...

Страница 13: ...s 40 C to 50 C 40 F to 122 F Temperature resolution 0 1 C 0 2 F Humidity Outdoor Operating Range 30 to 80 Resolution 1 Accuracy 7 Sampling Interval 10 seconds Transmitting Interval around 47 seconds R...

Страница 14: ...nly and is non transferable Meade products purchased outside North America are not included in this warranty RGA Number Required Prior to the return of any product or part a Return Goods Authorization...

Страница 15: ...Meade Instruments Corp 27 Hubble Irvine CA 92618 U S A 2011 Meade Instruments Corp All Rights Reserved All user manual contents and information are subject to change...

Отзывы: