Meade Magellan II Скачать руководство пользователя страница 5

This command identifies objects in the field of view of the telescope. By pressing ENTER Magellan displays the 
central object's description (i.e. the name, type, magnitude and size). Pressing ENTER again displays its coordinates 
in Right Ascension and Declination. A third press of ENTER displays the distance to the object from the telescope's 
current position.  

The MODE key aborts the selected menu item and returns to the previous menu list.  

d) Parameters

  

Start Find uses the specifications listed below to filter the database for matching objects. Scroll through these 6 
specifications using the PREV/NEXT keys and select the ones to change by pressing ENTER.  
 

1) Type

  

This menu file option allows you to select the type of CNGC objects you wish to locate. The symbols GPDCO 
represent:  

G Galaxies 
P Planetary Nebulae 
D Diffuse Nebulae 
C Globular Star Clusters 
O Open Star Clusters 

Initially, the blinking cursor appears over the G symbol. If you decide not to look for galaxies, press the PREV/NEXT 
key and the letter will disappear, deselecting the GALAXIES category. If you wish to leave GALAXIES selected, then 
move the blinking cursor over to one of the other category symbols by pressing ENTER. You can then deselect the 
undesired categories. If you wish to recall a category symbol, move the blinking cursor over the symbol location and 
press the PREV/NEXT key. After your selections are made, press ENTER.  

2) Better

  

The BETTER menu file option allows you to define the visual object quality range. At power up, the range is set at the 
bottom of the scale on VP. When using the START FIND menu selection, it will select all objects that are very poor 
through super or what could be considered an "ALL" setting. The object quality symbols are:  

SU Super 
EX Excellent 
VG Very Good 
G  Good 
FR Fair 
PR Poor 
VP Very Poor 

If you wish to define the visual object quality range to very good and better, press ENTER and the blinking cursor will 
appear on the quality value. From the quality setting press PREV/NEXT to move to higher or lower quality settings. 
Once you have selected the quality value required, press ENTER to complete the selection process.  

3) Larger

  

The LARGER menu file option allows settings of the lower apparent size limit of the objects you wish to see. At power 
up, it is set to 000' (arc minutes). In order to make a decision as to the size limits that you may impose, it helps to 
have a clear understanding of exactly what an arc minute of sky is. A good example is the apparent size of the Moon, 
which could be expressed as 1/2 degree, 30 arc minutes, or 1800 arc seconds. Each arc minute is 60 arc seconds, 
and there are 60 arc minutes for each degree of sky.  

Some beginning observers have a tough time discerning objects less than about 1 arc minute in size unless it is a 
double star or a planet. Astrophotographers and those involved with CCD imaging may want to set a higher value 
based on a desired image scale coverage that would be most impressive with different films or types of CCD 
cameras. Enter the new value in arc minutes by pressing ENTER to indicate that editing is required. This will cause 
the cursor to blink on the first digit of the sequence. Pressing a number key on the handbox will enter that number into 

Содержание Magellan II

Страница 1: ...nt to any object in the sky Telescopes with clock drives like the Meade Starfinder Equatorial have the axis of rotation such that rotation about the celestial pole is possible This is called a Polar configuration Magellan is a sophisticated microprocessor system that is programmed to understand the relationship between the moving sky and Polar configurations of a telescope For the Magellan to oper...

Страница 2: ... operation are found in the Serial Interface section of this manual III Hand Controller A Liquid Crystal Display The large Liquid Crystal Display LCD has two rows of 16 characters for displaying Magellan function menus telescope position and object information The LCD has red LED s to back light the display and can be adjusted to 16 levels of brightness B Keys Magellan II has a 19 key back lighted...

Страница 3: ...isplay LED s associated with each key along the right side of the handbox Keys 2 3 5 6 and 9 are used as catalog selection keys when not in an editing mode The CNGC Catalog can be selected by pressing the CNGC key 3 The Star Catalog and Planets can be selected by pressing the STAR key 6 The Messier Object Catalog is selected using the M key 9 The IC Catalog is selected by pressing the 2 key The Us...

Страница 4: ... telescope to the object As you move to various parts of the sky you may find that object positions differ slightly from the position indicated by Magellan These differences arise from inaccuracies in leveling squaring or centering stars during the initial alignment You can make minor corrections to the alignment by synchronizing Magellan on any object within the Magellan catalogs This is done by ...

Страница 5: ...nge is set at the bottom of the scale on VP When using the START FIND menu selection it will select all objects that are very poor through super or what could be considered an ALL setting The object quality symbols are SU Super EX Excellent VG Very Good G Good FR Fair PR Poor VP Very Poor If you wish to define the visual object quality range to very good and better press ENTER and the blinking cur...

Страница 6: ...isplay the first of these 125 possible selections Pressing PREV NEXT will scroll through the user items Press ENTER to select a particular user item that you want changed or added Pressing PREV NEXT will move you through the catalogs options press ENTER when you have the object library you wish to choose from You may then enter the object number with the keypad as in previous menus followed by ENT...

Страница 7: ...s shipped with your telescope If the standard value of the encoder is different due to a change in gear ratios a note will appear in the installation instructions which will direct you to change this ratio setting Press ENTER to select the Encoder function and change the ratios as needed by using the keypad as in previous examples 5 Reverse N S The Reverse N S menu selection reverses the direction...

Страница 8: ... original condition A short duration press of ENTER will start the timer counting down Pressing ENTER quickly will toggle the timer from running to stopped and stopped to running When running the timer will continue to count down even if the display is not visible Upon returning to the timer display the time remaining will be accurate and available to the user 2 Local Time The local time display s...

Страница 9: ...ion and observing conditions used to obtain the visual quality ratings It is a good indication of what can be expected with similar equipment by experienced deep sky observers in excellent sky conditions Naturally smaller telescopes and or less optimal observing conditions will lower the apparent quality of all objects B IC The Index Catalog IC is an extension of the NGC catalog and includes objec...

Страница 10: ...ble 1 Magellan II RS 232 Connector Pin Out Code Legend VII Appendix A The following stars from the STAR catalog are excellent beacons for alignment and are used in that process They are also spread throughout the sky to allow allowing a selection of several during any given night or season They also make excellent objects for the synchronize function of Magellan which will improve the pointing acc...

Страница 11: ...Star Charts for Northern Hemisphere observers part 1 ...

Страница 12: ... trademarks registered with the United States Patent Office and in principal countries throughout the world Copyright 2003 Meade Instruments Corporation All Rights Reserved This document was created soley for the purpose of off line viewing of the instruction manual for the Meade MagellanII DSC ...