background image

DOWNLOAD AND CLONE FROM AUTOSTAR

Use the following procedure to transfer information from one
AutoStar (

Clone

) to another AutoStar (

Download

):

1.

Verify that telescope power is OFF.

2.

Connect each AutoStar to its respective telescope.

3.

Connect the 3-foot cable (1, Fig. 2) between the RS-232
ports at the base of each AutoStar as shown in Fig. 2.

4.

Apply power and complete basic initialization as detailed
in the AutoStar instruction manual.

5.

On the AutoStar that is to 

receive 

information:

In the AutoStar 

Setup 

menu, scroll to the 

Download

option and press ENTER. This warning appears on the
screen:

NOTE: This sets AutoStar into a standby mode.

6.

On the AutoStar that is to 

send 

information:

In the 

Setup 

menu, scroll to the 

Clone 

option and press

ENTER. Scroll to one of three options:

Catalogs:

Sends only the user-defined object

information, such as new satellite orbital data, to
another AutoStar.

Software:

Sends only the basic AutoStar software.

This is useful if your AutoStar is equipped with a new
version of the AutoStar software (available from the
Meade web site) and you want to download the new
software to another AutoStar owner.

All: 

Transfers everything (

i.e.

, user-defined information

and AutoStar software).

WARNING: Downloading 

Catalogs 

or 

All 

will

overwrite any user-defined objects already in the
AutoStar database. Do not download either of these
options unless you wish to substitute new
information from the cloning AutoStar for all existing
user-defined information, such as orbital data on
comets or satellites.

7.

Press ENTER on the chosen option (

Catalogs

Software

,

or 

All

). The sending AutoStar starts to transfer information

to the receiving AutoStar (set in the 

Download 

mode in

step 5).

8.

At the completion of the transfer, the sending AutoStar
returns to the previous menu; the receiving AutoStar
beeps and automatically starts the initialization sequence.

9.

Complete the AutoStar initialization sequence, then turn
off telescope power and disconnect the cables between
AutoStar handboxes.

AutoStar cloning and downloading is now complete.

If you have a question concerning use of the #505 Connector
Cable Set, call the Meade Instruments Customer Service
Department at (949) 451-1450, or fax at (949) 451-1460.
Customer Service hours are 8:00 AM to 5:00 PM, Pacific Time,
Monday through Friday.

Ver. 0805

Part no. 14-4010-06

Fig. 2:

#505 Connector Cable Set connects between two AutoStar

handboxes. (1) 3-foot cable.

MEADE

MEADE

1

ENTER

GO TO

MODE

4

78

5

23

6

9

0

?

HBX

MEADE

MEADE

1

ENTER

GO TO

MODE

4

7

8

5

2

3

6

9

0

?

HBX

“Clone”

“Download”

1

Downloading
Do not turn off.

(800) 626-3233

www.meade.com

Отзывы: