6
DEHUMIDIFIER SETUP AND USE
Place the dehumidifier in an upright position on a stable, flat surface.
Please ensure the unit is a safe distance away from a wall or furniture.
The unit will bleep three times when the power cord is inserted into the socket.
Run the hose to a drain point no more than 3.5 metres above the height of the drain on the dehumidifier.
Press the Power button
. The dehumidifier will start up in Continuous dehumidification mode.
Select the Mode that you want to use the dehumidifier in using the
button.
To turn off press the Power
button again.
Pump Operation
When the internal tank is full the dehumidifier will automatically turn the pump on for two minutes. When this happens
the Pump icon on the LCD will flash. Before you turn the dehumidifier off you can press the Pump button to manually
drain the excess water from the internal tank. We recommend doing this before moving the dehumidifier to prevent
spillage. Water can also be drained by removing the drainage stopper from the base of the dehumidifier.
Timer Operation
To reset the Run Timer press and hold the
and
button for 8 seconds.
High and Low temperature protection
If the air inlet temperature and relative humidity sensor reads
≤0°C or ≥40°C then the dehumidifier will stop running and
the buzzer will sound three long notes and two short notes. In this situation the buttons will cease to respond when
pressed. When the temperature returns to normal please unplug the dehumidifier and then plug it back in again so
that it will start to operate normally again.
Compressor Protection
In common with other dehumidifiers the Meaco 70Lm will
not start up it’s compressor within three minutes of start up.
To operate safely
Do not insert small objects into the unit or this will damage it and cause a hazard.
Do not remove the tank when the dehumidifier is running or water may leak.
Minimum operating condition 5°C at 50%rh relative humidity.
ATTENTION !
Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or
allow it to come into contact with sharp edges.
Failing to follow the instructions may lead to the guarantee becoming void.