INSTALLING THE COMPRESSOR UNIT
8.
Optional Supply of After Cooler for Diesel Engine Driven Compressor Unit.
It is important for the majority of air tools that the air supplied should be free of moisture. High content
of moisture in the air will considerably reduce the reliability and life of the air tool. In applications such
as painting with air guns, the finish can be greatly affected by moisture in the air.
Filters used in the standard filter regulator lubricator units have a limit to what they can handle. It is
suggested in areas of high humidity or in situations where the standard FRL is not able to cope with
the moisture that a MEA AFTERCOOLER (Part Number 7201-B0020) is installed onto the
compressor unit. A MEA water separator can be installed with an electric solenoid operated drain
valve Part Number (See Accessories). The following picture shows the MEA AFTERCOOLER
installed onto a SMAC-D.