4.9

 

Convert

 

RS232

 

Byte

 

status

 

into

 

KNX

 

Bit

 

values

 

 

The

 

following

 

figure

 

shows

 

the

 

available

 

settings

 

for

 

this

 

parameter:

 

 

Figure

 

10:

 

Convert

 

RS232

 

Byte

 

status

 

into

 

KNX

 

Bit

 

values

 

 

This

 

function

 

enables

 

converting

 

a

 

byte

 

status,

 

which

 

is

 

sent

 

from

 

the

 

Multimedia

 

Device

 

and

 

contains

 

several

 

states,

 

into

 

individual

 

bit

 

values.

 

The

 

received

 

byte

 

value

 

is

 

divided

 

into

 

8

 

Bit

values

 

and

 

the

 

Bit

 

0

 

is

 

sent

 

to

 

object

 

140,

 

the

 

Bit

 

1

 

to

 

object

 

141.

 

 

Example:

 

Bit0

  

Speaker

 

zone

 

1

      

=>

 

Obj

 

140

 

Bit1

  

Speaker

 

zone

 

2

      

=>

 

Obj

 

141

 

Bit2

  

Speaker

 

zone

 

3

      

=>

 

Obj

 

142

 

Bit3

  

Speaker

 

zone

 

4

      

=>

 

Obj

 

143

 

 

bit7

 

System

 

on

                         

=>

 

Obj

 

147

 

 
 

 

Содержание SCN-MMG01.01

Страница 1: ...MDT technologies GmbH 51766 Engelskirchen Papierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 1 11 2013 Technical Manual MDT Multimedia Gateway SCN MMG01 01...

Страница 2: ...rence ETS Parameter 6 4 1 General 6 4 2 Header Footer 7 4 3 KNX RS232 1 Bit 8 4 4 KNX RS232 1 Byte 8 4 5 RS232 Bit value 9 4 6 RS232 Byte value 9 4 7 RS232 Text String 11 4 8 Macro functions 12 4 9 Co...

Страница 3: ...timedia devices to the KNX Bus Connection between Multimedia Gateway and Multimedia device is established by a RS232 interface which is included in delivery The Gateway offers prepared settings for de...

Страница 4: ...ess 100 109 RS232 KNX Status The received value of the Multimedia device causes sending a 0 command or a 1 command via this communication object Different telegrams can be adjusted for sending a logic...

Страница 5: ...X X X 110 109 Object 110 109 RS232 KNX Status 1 Bit Low X X X 120 129 Object 120 129 RS232 KNX Status 1 Byte Low X X X 130 134 Object 130 134 RS232 KNX Status Text 14 Byte Low X X X 135 140 Object 13...

Страница 6: ...eneral The following figure shows the general settings Figure 2 General settings At this menu the general settings of the device must be recorded If one of the predefined producers is in use this prod...

Страница 7: ...hree header and footer can be adjusted The Header is put in front of the telegram and the footer is put at the end of the telegram Which Header and Footer shall be used can be adjusted for each group...

Страница 8: ...e only at a 1 command The transmitted telegram contains of the adjusted Header here H1 the adjusted telegram the adjusted Footer here F1 4 4 KNX RS232 1 Byte The following figure shows the available s...

Страница 9: ...ts 100 to 109 telegrams can be adjusted as well for sending a logical 0 and a logical 1 At the objects 110 to 119 telegrams can only be adjusted for sending a logical 1 The whole telegram with Header...

Страница 10: ...hortened e g for fading out the Checksum Example The information of the length in the telegram is 10 but this information contains parts of the command so the real length of the text must be shortened...

Страница 11: ...of the string is included in the telegram o if yes Text length reduce by indicates if the text shall be shortened e g for fading out the checksum o if no Exact length adjustment of the length of the...

Страница 12: ...tions Figure 9 Macro functions The Macro functions enable the sequential sending of multiple commands via activating one object Up to 7 commands can be selected for each macro For selecting the comman...

Страница 13: ...his parameter Figure 10 Convert RS232 Byte status into KNX Bit values This function enables converting a byte status which is sent from the Multimedia Device and contains several states into individua...

Страница 14: ...To the end of the telegram without checksum are 3 bytes remaining Offset of length specification 3 So the whole length of the telegram is defined The data end timeout can be adjusted to the minimum va...

Страница 15: ...parameter Bit Object 0 39 KNX RS232 Value 0 1 Here the value 0x57 must be signed in for this parameter which switches the device on or off The next example for T A Amplifier is a telegram for adjusti...

Страница 16: ...elegrams Byte 1 and 3 At the settings for the objects 120 129 this telegram must be signed in the line for telegram 120 The Header and the address Byte 1 and 3 are inscribed 1 1 for the parameter Byte...

Страница 17: ...ssible to perform several commands The object numbers and values can be assigned user defined Example for the Macro function 1 3 Commands are performed with the object 135 1 Switch the device on via t...

Страница 18: ...st be transmitted Figure 17 Example 2 general functions For performing a command with a 1 Bit value the Clear text values with the appropriate commands must be signed in Figure 18 Example 2 1 Bit comm...

Страница 19: ...1 6 1 7 1 8 1 9 2 0 2 1 2 2 F 0 0 0 0 0 7 F 0 0 0 0 7 0 0 5 0 2 0 2 0 0 0 0 F 1 2 3 0 0 0 1 0 0 0 0 0 0 0 1 X X F 7 Table 6 Example 3 Telegram Russound Byte 22 is the end of the telegram Figure 20 Ex...

Страница 20: ...pierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 20 Bytes 6 to 20 are the command of this telegram So these values are signed into the parameter Figure 23 Example 3 1 Bit command At...

Страница 21: ...ings 14 Figure 12 Example 1 Settings for Header 14 Figure 13 Example 1 Setting for Footer 15 Figure 14 Example Macro 1 Function 1 17 Figure 15 Example Macro 1 Function 2 17 Figure 16 Example Macro 1 F...

Страница 22: ...age can occur danger for humans animals or material assets Do not let the packaging lying around careless plastic foil bags etc can be a dangerous toy for kids 7 2 Routine disposal Do not throw the wa...

Страница 23: ...y rooms For project design and commissioning of the Multimedia Gateway it is recommended to use the ETS3f ETS4 or later Please download the application software at www mdt de Downloads html Production...

Страница 24: ...minal 0 8mm solid core Supply voltage KNX Bus Power consumption KNX bus typ 0 3W Operation temperature range 0 to 45 C Enclosure IP 20 Dimensions MDRC Space Units 2SU MDT technologies GmbH 51766 Engel...

Отзывы: