MDS 05-3627A01, Rev. D
LEDR Series I/O Guide
71
linelist—
Represents a list of local line interfaces. It can consist of a single
line number or line name, a comma-separated list of line numbers or line
names, a range of line numbers (i.e., 1–4) or, if linelist is not given, all
lines. See
on Page 59 for a list of line numbers.
on|off
—To turn the loopback feature on or off.
-u <code>
—Allows setting of the inband|outband loopback upcode.
The inband code consists of 1-7 bits, binary format.
Example: 00001
-d <code>—
The subcommand allows setting of the inband|outband loop-
back downcode.
The outband code consists of 6 bits within the 16 bit ESF data
link codeword.
Example: 000111
within 16 bit codeword: 0<000111>0 11111111
model
Radio Model Number
Usage:
model
This command displays the radio model number. This information is
programmed at the factory and cannot be changed.
modem
Modem
Usage:
modem [matrix id] [+cas]
This command sets or displays the radio modem modulation type and
data rate.
shows the alphanumeric codes that can be entered for
for codes for subrate radios. Note that the
E1 selections are only valid on fullrate radios.
1. The available selections depend on the radio’s factory programmed bandwidth. See
for the allowable combinations of bandwidth, data rates and
modulation types.
Table 24. Modem Command Arguments for E1 (Fullrate) Radios
1
DATA RATES
Modulation
Type
1xE1
2xE1
3xE1
4xE1
QPSK
A7
—
—
—
16 QAM
B7
B8
—
—
32 QAM
C7
C8
C9
C10