MDS Power VTCi320 Скачать руководство пользователя страница 6

Operation

The VTCi320 Voltage Converter is designed for simple operation. It is intended to operate fully 

unattended and will attempt to recover from any fault, including Over-Temperature, Low Input 

Voltage, Input Power Failure and Overload.

TO OPERATE

1. Press the Power Button on the unit’s front panel. It will start glowing.

2. The voltage converter will go through its startup sequence. All 6 microprocessor-

controlled LEDs flash red and then green. When the Power Button starts glowing, the

sequence is complete.

3. The VTCi320 will automatically supply the load with the voltage indicated on its label for

as long as the load is connected.

4. The Indicator LEDs can be used to determine the amount of current being drawn by the

load. See the diagram below.

BLINKING

75

CURRENT > 11-39%

IP

TEMP

25

DEV

75

FAIL

FLT

LO V

OP

50

CURRENT = 100%

IP

POL

TEMP

25

DEV

75

FAIL

FLT

LO V

OP

50

CURRENT >85%

IP

TEMP

25

DEV

75

FAIL

FLT

LO V

OP

50

CURRENT > 40-59%

IP

TEMP

25

DEV

75

FAIL

FLT

LO V

OP

50

CURRENT < 10%

IP

TEMP

25

DEV

75

FAIL

FLT

LO V

OP

50

CURRENT > 60-84%

AC

TEMP

25

DEV

CH

75

FAIL

FLT

LO V

OP

50

EQ
PS

TO END OPERATION

1. Press the Power Button on the unit’s front panel.

2. The voltage converter will beep and the LED indicators will stop glowing.

3. When all the LEDs are dim, the unit is safe to disconnect from the load and power source.

4. The unit can now be safely serviced or put into storage.

TO INSTALL

1. Connect the Voltage Converter to the load before con-

necting the input power.

2. Connect the Power Supply to the input power. The IP

LED should illuminate indicating it is receiving power.

IP

TEMP

25

DEV

75

FAIL

FLT

LO V

OP

50

6

Содержание VTCi320

Страница 1: ...INSTALLATION OPERATION MANUAL VTCi320 INTELLIGENT VOLTAGE CONVERTER T 514 369 4919 TF 800 931 4919 www mdspower com...

Страница 2: ...converter directly above a battery gases from the battery will corrode and damage the voltage converter 6 Never allow battery acid to drip onto the voltage converter MEDICAL EQUIPMENT NOTICE This uni...

Страница 3: ...Product Warnings and Advisories Table of Contents Introduction Box Contents Main Parts Operation Installation Front Panel Adjustments Maintenance Dry Contact Relay Definitions and Abbreviations Troubl...

Страница 4: ...systems Internally LLC Resonant Converter technology allows Zero Voltage Zero Current switching on the primary or high voltage side of the main power transformer Multiple stages of filtering ensures u...

Страница 5: ...6 DC Output Connection 2x Phoenix VDFK Terminal Block Connetions Red Positive Black Negative 7 Chassis Ground Stud Front Panel 2 3 7 6 1 5 4 Rear Panel Not shown 1 AC Power Input Connection 1ft 30cm T...

Страница 6: ...ing drawn by the load See the diagram below BLINKING 75 CURRENT 11 39 IP TEMP 25 DEV 75 FAIL FLT LO V OP 50 CURRENT 100 IP POL TEMP 25 DEV 75 FAIL FLT LO V OP 50 CURRENT 85 IP TEMP 25 DEV 75 FAIL FLT...

Страница 7: ...Terminal Normally these leads should be adequate to connect to the DC power source however if you must extend the leads be sure to Use the smallest extension length possible Use a good quality typeTEW...

Страница 8: ...e fuses have been replaced Max Output Current 24 00 A 15 00 A 9 30 A 5 90 A 3 70 A American Wire Gauge 8AWG 10AWG 12AWG 14AWG 16AWG Max Output Current 2 30 A 1 50 A 0 92 A 0 58 A 0 23 A American Wire...

Страница 9: ...e state The Normally Open contact operates exactly in the reverse of the Normally Closed contact Abbreviations and Definitions We use a number of abbreviations on the labels to save space Here are the...

Страница 10: ...it will shut off and wait for the voltage to recover OVERTEMP IP TEMP FAIL LO V IP TEMP 25 DEV 75 FAIL FLT LO V OP 50 Over Temperature Indication The voltage converter has detected that its internal t...

Страница 11: ...rating Temperature Range 25 C to 40 C 40 C to 55 C Optional Storage Temperature Range 55 C to 85 C Humidity 0 95 Relative Humidity non condensing Emissions Complies with FCC Class B Part 15 Isolation...

Страница 12: ...800 931 4919 514 369 1919 order mdspower com www mdspower com DESIGNED AND BUILT IN CANADA...

Отзывы: