background image

OPERATING AND 

USERS MANUAL

UK

www.mdpelectronics.fr

12V-10A
12V-15A
12V-25A
12V-40A
24V-20A

BATTERY CHARGER

FIRST

Содержание 12V-10A

Страница 1: ...Operating and users manual UK www mdpelectronics fr 12V 10A 12V 15A 12V 25A 12V 40A 24V 20A BATTERY CHARGER FIRST...

Страница 2: ...device Before Installation 4In order to avoid overcharging or irreversible damage to the materials please follow closely all recommendations cited below Do not install this system near inflammable mat...

Страница 3: ...try of use 4In order to protect the occupants the input point must be attached to a differential circuit breaker Please refer to the specific characteris tics of the circuit breaker 4For security reas...

Страница 4: ...c and conducted superior to those legally permit ted for example the devise installed too close to an emitter as this may cause irreversible da mage 4This device emits interference electromagnetic and...

Страница 5: ...tenance precautions 4This device cannot be dismantled and thus the PC board is inaccessible It is strictly forbidden to dismantle the housing for any reason Electric shock possible 4In order to preven...

Страница 6: ...tput overload output short circuit excessive internal temperature excessive battery temperature output overvoltage battery reverse polarity fuse General Display Tricoloured LED Night mode Diagram B Bu...

Страница 7: ...1 9 kg 4 2lbs V 4mm_max WINSTA WAGO V 10mm_max PHOENIX CONTACT A 12V 40A 24V 20A TECHNICAL SPECIFICATIONS FIRST rev 01 UK Button Night Mode Diagram B Input Tension 230V 15 115V please consult us 115V...

Страница 8: ...s The batteries are completely charged The charger is on Standby for a period of between 30 seconds and 10 minutes Once the fault has been solved the device will start up again automatically 4If this...

Страница 9: ...2 5 mm2 12 AWG 12V25A 4 0mm2 10 AWG 12V40A 6 0 mm2 8 AWG Lg cables 1 5 m 4 9 feet max Recommended cable size 12V10A 3 x 0 75 mm2 18 AWG 12V15A 3 x 0 75 mm2 18 AWG 12V25A 3 x 1 5 mm2 14 AWG 12V40A 3 x...

Страница 10: ...the security cap using an utility knife 7Step 3 Pull the conductor through the pre latched strain relief housing 7Step 4 Open the clamp with a screwdriver and insert the first cable up to the stop Rep...

Страница 11: ...10A 12V 15A Dimensions 12V 25A 12V 40A 24V 20A x2 5mm 20mm 0 79inch 95 6mm 3 76inch 120mm 4 74inch 238mm 9 37inch 210mm 8 27inch 352 5mm 13 88inch 326mm 12 83inch 120mm 4 74inch 95 6mm 3 76inch 20mm...

Страница 12: ...the device 4Interfering with or modifications made to the PC Board may result in unforeseen operations and consequently may cause the malfunction of or damage to the device 4Use of a non adapted powe...

Страница 13: ...ses 4Charging curve 4 is compatible with LiFeSo4 batteries that have a BMS battery management system installed 4It is essential to consult the battery manufactu rer s recommendations Disposal This dev...

Страница 14: ...further information or assistance please contact mdp electronics 144 route des Vernes 74370 Pringy FRANCE T l 33 0 450 272 030 Fax 33 0 450 272 774 e mail contact mdpelectronics fr www mdpelectronics...