MDI MD500T Скачать руководство пользователя страница 3

 

SAFETY INSTRUCTIONS 

Please read and understand this entire manual before attempting to assemble, operate or install the product.
Failure to comply with instructions and designed operation of this system may void warranty. 

ATTEMPTING TO

USE A DAMAGED PUMP

 can result in personal injury or death!

Safety Precautions

1.

Know the pump applications, limitations, and potential hazards.

2.

Do not lift pump by power cord or switch cord.

3.

Do not touch an operating motor housing. The motor is designed to operate at high temperatures.

4.

Do not disassemble the motor housing. Motor has been filled at the factory with special oil. In normal service,
motor should not need oiling. The motor has NO repairable internal parts, and disassembling it may cause
oil leakage or dangerous electrical wiring issues.

5.

Make certain the electrical power source is adequate for the requirements of the pump.

6.

ALWAYS disconnect the power to the pump before servicing.

7.

Release all pressure within system before servicing any component.

8.

Drain all water from system before servicing.

9.

Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing
personal injury and/or property damage.

10.

Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation to
maximize pumping efficiency and prevent clogging and premature pump failure.

11.

Check that all pipe connections are tight to minimize leaks.

12.

Connect the pump DIRECTLY to a grounded, GFCI outlet.

13.

Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life
threatening safety hazard if the insulation becomes damaged or the connection ends fall into water.

14.

Make certain the electrical circuit to the pump is protected by a 15 Amp or larger fuse or circuit breaker.

15.

 Periodically inspect the pump and system components. Perform routine maintenance as required. Do

not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water.

16.

Wear safety glasses at all times when working with pumps.

17.

Follow all electrical and safety codes, particularly the Canadian Electrical Code, and local codes and
ordinances.

18.

This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN UNDER ANY
CIRCUMSTANCES. The 3-prong plug must be directly inserted into a properly installed and grounded
3-prong, grounding-type receptacle. 

Do not use this pump with a

 2-prong wall outlet. Replace the 

2-prong outlet with a properly grounded 3-prong receptacle (

a GFCI outlet

) installed in accordance with

the Canadian Electrical Code and local codes and ordinances. All wiring should be performed by a
qualified electrician.

 

19. 

Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. 

Do

not use damaged or worn cords.

Содержание MD500T

Страница 1: ...USE AND CARE GUIDE SUBMERSIBLE SEWAGE PUMP Model MD500T MD500T G MD500T V MD500T G SHOWN...

Страница 2: ...imming pools or in salt water marine areas It is also not engineered to be run continuously as a fountain or waterfall pump Do not pump flammable or explosive liquids such as oil gasoline kerosene eth...

Страница 3: ...pump failure 11 Check that all pipe connections are tight to minimize leaks 12 Connect the pump DIRECTLY to a grounded GFCI outlet 13 Extension cords may not deliver sufficient voltage to the pump mo...

Страница 4: ...ng Check valve should be a free flow valve that will easily pass solids NOTICE For best performance of check valve when handling solids do not install it with discharge angled more than 45 above the h...

Страница 5: ...over the pump top The water will be pumped out When the water lowers to certain level the float switch will turn off the pump 3 NOTICE If the overload protector stops the pump repeatedly disconnect t...

Страница 6: ...mp Replace switch Pump will not turn on unless water level is over the pump cover and the float switch turns upside down Reposition the pump and make sure switch moves freely Pump operates but pumps l...

Страница 7: ...r replaces defective pumps at MDI s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as the prob...