Ice Fog User
Guide
- June 2002
3
LED Status
:
FOG Green LED indicates that the generator is producing fog.
DELAY Yellow LED indicates that the delay is activated and won’t produce fog until it is turned off.
FLUID VALVE Green LED indicates that the fluid solenoid valve is on and should turn on and off with the FOG LED.
CO
2
VALVE Green LED indicates that the liquid CO
2
solenoid valve is on.
Fog Output Delay
:
Delay of 3 to 30 seconds.
Allowing to cool down
the cold chamber of the
Generator.
Fog Output adjustment:
Pressure regulator &
gauge
Maximum Operating
pressure 4.14 bar (60 psi)
Pressure Switch
:
Upward position will pressurize the Fluid Reservoir.
Downward position will depressurize allowing to refill
the Fluid reservoir.
Operating Pressure:
Refrigerated low pressure liquid CO
2
input
1500 kPa (225 psi) ± 10%
Power Cord
208 or 230 VAC
Main Power switch
Detacheable standard
remote control
See picture below
Green LED indicates that the
Generator is READY to
operate
Fog switch with a Green
LED indicator
XLR-5 Remote Control Connector
HEAT yellow LED indicator
1) The LED turns on and off
from time to time to indicate the
control of temperature.
2) The LED will start blinking
indicating the FAIL mode.
Power switch with the Red LED
Standard remote control MT35A-n