Heater Control
The control switch panel is used to control the unit functions.
1. Ventilation mode indicator
2. Heating/Combustion mode indicator
3. Heating selector button
4. Stop button
5. Ventilation selector button
6. Temperature selector
Important tips about operation
•
Do safety check before initial starting of the heater. Check all components for secure fit (tighten screws where
necessary). Carry out a visual check whether fuel system, combustion air system, exhaust system is unobstructed.
•
Normal operation of heater at altitudes up to 1500 m.
•
Heater can be used for short periods at altitude 1500 - 3000m. Over 3000m, the heater must be customized.
•
During the initial start-up of the heater, odours can be produced for a short time. This is fully normal during the first
few minutes of operation and does not indicate a malfunction in the heater.
•
During the initial start-up of the heater, there may be an alarm caused by ignition failure. This is because fuel is
needed to fill in fuel pipe. Restarting heater nominally should rectify this.
Operating instructions
•
Pressing ventilation button on switch will activate the fan only. This will operate without combustion to ventilate the
area.
•
Pressing the heating selector button will start the combustion process and begin heating mode. Combustion and
ventilation lamps light up simultaneously.
•
As a fault occurs during operation of the heater, combustion indicator light flashes to indicate cause of the
malfunction.
•
Pressing the stop button. The heater stops working (combustion or ventilation). After delayed stop, the light goes
out.
•
Temperature regulating knob is used for setting temperature for the heater’s automatic temperature control.
Adjustment range is 10-30 ° C.
•
Switch between ventilation and combustion state is possible.
•
When switching off from heating mode, allow the unit to run on ventilation mode until the unit cools. This will
prevent fumes.
Switching on
•
Press heating mode button on control switch, combustion and ventilation indicating light lights up. Then, heater
starts running with glow plug working and fan running at low speed.
•
If there is still too much residual heat in the heat exchanger from when the heater was last used, firstly only the fan
starts up (cold blowing). Once the residual heat has been cleared, the heater starts.
Heating process
•
After approx. 60 seconds the fuel supply starts and the fuel / air mixture in the combustion chamber ignites.
•
After the flame sensor has detected the flame, the glow plug is switched off after approx. 90 sec. The heater has
reached the “POWER” stage gradually (maximum fuel quantity, maximum fan speed).
Содержание XT16HR ISLAND 2021
Страница 38: ...www marketdirect com au Ph 1300 494 494 34...
Страница 46: ...www marketdirect com au Ph 1300 494 494 42 12 Volt Wiring Diagram Main Circuit...
Страница 47: ...www marketdirect com au Ph 1300 494 494 43 Wiring Diagram Switch Panel...
Страница 59: ...www marketdirect com au Ph 1300 494 494 55 Schematic...
Страница 68: ...www marketdirect com au Ph 1300 494 494 64 Trouble Shooting Electrical...
Страница 78: ...www marketdirect com au Ph 1300 494 494 74 Trip Name Date Km Start Km Finish Cumulative Km...
Страница 81: ...www marketdirect com au Ph 1300 494 494 77 Hub Assembly...
Страница 82: ...www marketdirect com au Ph 1300 494 494 78 Trailing Arm Bushes...