www.marketdirect.com.au
I
Ph: 1300 494 494
I
©Copyright
I
P a g e
|
64
MkII Diesel Heater
Operation
1-Control Knob
2- Heating (power on) mode button
3-Heating (power on) indication light
4-Constant temperature indication light
5- Constant temperature mode button
6-Ventilation mode button
7 -Ventilation indicating light
Heater Control Switch
Power on
Press the heating (2 power on) button, the heating (constant power) will flash for 0.3S. The heater will begin the
start stage. The controller will run heating the program according to the temperature control target set by the
control knob. In the start stage, the time delay from switch-on to fuel supply to the fuel pump is around 65
seconds.
Temperature Control
When the combustor is ignited and running, you can turn the control knob according to the arc mark around the
control switch (1) to control the temperature.
Ventilation mode
You can only enter the ventilation mode when you press the ventilation mode key to start the heater. The
ventilation indicating light turns green after pressing ventilation button. Heater can only circulate air without any
heating. The fan speed can be continuously regulated with the control knob.
Shutdown
To shut down the unit, press the button indicative of the current mode of operation. If the fuel pump is at work
before the heater is turned off, the pump will shut down immediately, but the fan will continue to run for 180
seconds.
*DO NOT TURN OFF MAIN SWITCH ON PANEL UNTIL THE UNIT HAS COMPLETED ITS SHUTDOWN PROCESS.
Содержание FORBES 12+
Страница 42: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 42...
Страница 53: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 53 Wiring Diagram Switch Panel Com ing Soon...
Страница 85: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 85 Hub Assembly...
Страница 86: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 86 Trailing Arm Bushes...
Страница 116: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 116...