www.marketdirect.com.au
I
Ph: 1300 494 494
I
Contents 61
Switching Off Gas Operation
–
Switch off the water heater to position (Fig. 3b - c).
If the water heater is not to be used for a longer period, mount cowl cover (non-observance of this point can
lead to the function of the appliance being impaired through water, dirt or insects), close stop cock valve in the
gas supply line and close the gas cylinder.
Before setting off on any journey, fit cowl cap with the Truma UltraRapid switched off. Please ensure that it is
secure and has locked into place (risk of accident). Defective cowl caps must not be used. Drain the water
heater if there is a risk of frost! Warranty claims will not be accepted if this is ignored.
Red Indicator Lamp “Fault”
The red indictor lamp (a) lights up if there is a fault. For possible causes please refer to “Fault finding” on page 6.
To unlock, switch off the appliance, wait 10 minutes, and switch on again.
Maintenance
Do not modify this appliance
Servicing should only be carried out by authorised personnel.
Only original Truma parts may be used for maintenance and repair work!
Please contact the Service Australia for service and repairs.
Decalcification
The Truma UltraRapid must be descaled on a regular basis (at least twice a year).
We recommend the use of suitable normal commercial products for the cleaning, disinfection and care of the
Truma UltraRapid. Products containing chlorine are unsuitable.
•
In order to avoid the colonization of micro-organisms, heat up the Truma UltraRapid to 70 °C at regular
intervals.
•
The drain valve (Fig. 2 - 3) and the P&T safety valve (Fig. 2 - 4) are to be operated regularly to remove
lime deposits and to ensure that they are not blocked. Frequency: every 6 month.
Fuses
The water heater 12 V fuse is on the PCB on the water heater.
Important note
Only replace the miniature fuse on the PCB with a fuse of the same type: 1.6 A (slow action).
Circuit Breaker
There is a circuit breaker allocated to the water heater circuit switch on the main electrical panel. To reset this
breaker, push in.
Содержание 15 Year Anniversary Edition XT 10E
Страница 45: ...www marketdirect com au IPh 1300 494 494 IContents 45 ...
Страница 55: ...www marketdirect com au IPh 1300 494 494 IContents 55 12 Volt Main Circuit Diagram ...
Страница 56: ...www marketdirect com au IPh 1300 494 494 IContents 56 12 Volt Switch Circuit ...
Страница 72: ...www marketdirect com au IPh 1300 494 494 IContents 72 Diagram E1 ...
Страница 81: ...www marketdirect com au IPh 1300 494 494 IContents 81 Trip Name Date Km Start Km Finish Cumulative Km ...
Страница 83: ...www marketdirect com au IPh 1300 494 494 IContents 83 Hub Assembly ...
Страница 84: ...www marketdirect com au IPh 1300 494 494 IContents 84 Trailing Arm Bushes ...