88
Indicator Lights
IR signal receiver
When there is infrared remote control operating signal, the signal receiver on indoor unit will made a
(beep) for signal acceptance confirmation.
The table below shows the LED indicator light for air conditioner unit under normal operation and fault condition.
The LED indicator lights are located at the middle of the air conditioner unit.
The heat pump units is equipped with an “auto” mode, whereby the unit will provide reasonable room temperature
by switching the unit automatically to either “cool” mode or “heat” mode, according to the temperature setting
set by the user.
LED Indicator Lights Display
COOL / HEAT
IONIZER
TIMER
SLEEP MODE
LED Indicator Lights : Normal Operation And Faulty Indication Table
COOL/HEAT
(GREEN/RED)
Normal Operation / Fault Indication
Action
/
/
/
Red
/
Green
Red
Green
Green
Red
/
/
Red
Cool mode
Heat mode
Auto mode in heating operation
Auto mode in cooling operation
Timer on
Sleep mode on
Ionizer on
Room air sensor contact Loose / Short
Outdoor coil sensor contact Loose / Short
Defrost operation
Compressor overload protection trip or
gas leask
Indoor coil sensor contact Loose / Short
Call your dealer
Call your dealer
Call your dealer
-
-
-
-
-
-
-
-
- ON
/
- ON or OFF
- Blinking
IR Receiver
LED indicator lights
Содержание M5WM 007G
Страница 42: ...Cooling Only Models Model MLC M5LC 020C M4LC 020B Model MLC M5LC 025C M4LC 025B 40...
Страница 43: ...Heatpump Models Model MLC M5LC 007CR Model M4LC 007BR 010BR MLC M5LC 010CR 41...
Страница 44: ...Model M4LC 015BR Model MLC M5LC 015CR 42...
Страница 45: ...Heatpump Models Model MLC M5LC 020CR M4LC 020BR Model MLC M5LC 025CR M4LC 025BR 43...
Страница 53: ...Cooling Only Models Outdoor Unit Model MLC 015C 51 Indoor Unit Model MWM 015G With Ionizer...
Страница 54: ...Cooling Only Models Outdoor Unit Model MLC M5LC 020C 025C 52 Indoor Unit Model MWM M5WM 020G 025G With Ionizer...
Страница 56: ...Cooling Only Models Outdoor Unit Model MLC 015C 54 Indoor Unit Model MWM 015G With NTP...
Страница 57: ...Cooling Only Models Outdoor Unit Model MLC M5LC 020C 025C 55 Indoor Unit Model MWM M5WM 020G 025G With NTP...
Страница 58: ...56 Cooling Only Models Outdoor Unit Model M4LC 007B 010B 015B Indoor Unit Model MWM 007G 010G 015G With Ionizer...
Страница 59: ...Cooling Only Models Outdoor Unit Model M4LC 020B 025B 57 Indoor Unit Model MWM M5WM 020G 025G With Ionizer...
Страница 60: ...58 Cooling Only Models Outdoor Unit Model M4LC 007B 010B 015B Indoor Unit Model MWM 007G 010G 015G With NTP...
Страница 61: ...Cooling Only Models Outdoor Unit Model M4LC 020B 025B 59 Indoor Unit Model MWM M5WM 020G 025G With NTP...
Страница 62: ...60 Cooling Only Models Outdoor Unit Oxygen Unit Model MLC 010C M5LC 010C 015C...
Страница 64: ...62 Heatpump Models Outdoor Unit Model MLC 015CR Indoor Unit Model MWM 015GR With Ionizer...
Страница 65: ...Heatpump Models Outdoor Unit Model MLC M5LC 020CR 025CR 63 Indoor Unit Model MWM M5WM 020GR 025GR With Ionizer...
Страница 67: ...65 Heatpump Models Outdoor Unit Model MLC 015CR Indoor Unit Model MWM 015GR With NTP...
Страница 68: ...Heatpump Models Outdoor Unit Model MLC M5LC 020CR 025CR 66 Indoor Unit Model MWM M5WM 020GR 025GR With NTP...
Страница 70: ...Heatpump Models Outdoor Unit Model M4LC 020BR 025BR 68 Indoor Unit Model MWM M5WM 020G 025G With Ionizer...
Страница 71: ...69 Heatpump Models Outdoor Unit Model M4LC 007BR 010BR 015BR Indoor Unit Model MWM 007GR 010GR 015GR With NTP...
Страница 72: ...70 Heatpump Models Outdoor Unit Model M4LC 020BR 025BR Indoor Unit Model MWM M5WM 020G 025G With NTP...
Страница 79: ...77 Installation Diagram Installation...
Страница 100: ...98 Model M5WM MWM 020G 020GR 025G 025GR...
Страница 118: ...2005 McQuay International 1 800 432 1342 www mcquay com...