Safety 

Meaning of symbol 

CAUTION! Please consult the operating instructions before using the device. In these operating instructions, failure to 

follow or carry out instructions preceded by this symbol may result in personal injury or damage to the device and the 

installations. 

 

Meaning of symbol 

This appliance is  protected by  double  insulation  or reinforced insulation.  It does  not  have  to be  connected to an  earth 

protection terminal for electrical safety. 

 

Thank you for purchasing this MS306 multimeter. 

To obtain the best service from your unit: 

- Read

 these operating instructions carefully, 

- Comply

 with the precautions for use. 

 

 

 

PRECAUTIONS FOR USE 

 

Never  use  on  a  voltage  network  over  600V  with  respect  to  the  earth  connection.  This  voltage  surge  category  III 

multimeter  complies  with  stringent  reliability  and  availability  requirements,  corresponding  to  fixed  industrial  and 

domestic installations (see IEC 664-1). 

 

Do not use on alternative and continuous voltages > 600V. 

 

Indoor use in environments with a maximum pollution level of 2 (EN 50419:2006) temperature of -10ºC to +50ºC 

and relative humidity below 90%. 

 

Respect the value and type of the fuses to avoid damaging the instrument and canceling the warranty. 

 

1A fuse 600V 

 

10A fuse 600V 

 

Use  accessories  corresponding  to  safety  standards  (EN  61010-1:2001)  with  600V  minimum  voltage  and  surge 

category III. 

 

Before any measurement, ensure correct positioning of the leads on the multimeter and of the switch. When the value 

range of a measurement is not known, place the switch at the highest caliber, and then gradually reduce it until the 

appropriate caliber is achieved: the reading should preferably be in the upper 2/3 of the range. 

 

Never measure resistances on a live circuit. 

 

During current intensity measurements (without a clip-on ammeter), stop circuit power supply before connecting or 

disconnecting the multimeter or changing caliber. 

 

The leads must be disconnected to open the lower half of the meter case 

 

Never connect to the circuit to be measured if the casing is not properly closed. 

 

 

 

 

 

 

 

 