background image

 

www.mcohome.com                                        User Manual

 

MCOHome Technology Co., Ltd 

                                  1 

 

Touch Panel Switch 

MH-S511 

 

                                                                     

Introduction       

                                                               

 

Touch  Panel  Switch  is  a  wall  switch  with  built-in  Z-Wave  module.  It  supports  basic  command 

class

association  command  class,  which  can  control  all  associated  devices  synchronously.  This 

product  can  be  included  and  operated  in  any  Z-Wave  network  with  other  Z-Wave  certified  devices 

from any other manufacturers. 

 

                                                                   

Specifications

                                                                         

Power supply: 85-260VAC, 50/60Hz 

Z-Wave frequency: 916MHz (IL).                                                                                       

   

 

Resistance load: 1*3.5A   

*

LED load: <3A total     

 

                                                         

Installation Instructions

                                                               

 

IMPORTANT:   

 

A  qualified  electrician  with  the  understanding  of  wiring  diagrams  and  knowledge  of  electrical 

safety should complete the installation inside the main circuit box (normally outside your house) 

 

Read all instructions and documentation and save for future reference 

 

Step1 Preparing   

CAUTION: 

Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock or 

death! 

 

Step2 Wiring   

( standard strip length: 6-8mm )

 

 

1. Separate the device into two parts: the touch panel and the bottom.   

2. Connect Hot Line to “L” on the bottom.       
3. Connect Neutral Line to “N”. 
4. Connect Load wire to “L1”.   

5. Secure the bottom onto the junction box with two screws, and then mount the touch panel back. 

 

* Note: If a higher output needed, pls choose model MH-S511H instead. (LED load: <10A , inrush current<165A/ 20ms )

 