User Manual
MCOHome Technology Co., Ltd
www.mcohome.com
4
Valve Output Voltage Display
In the state of power on/off
,
long press
to enter into valve output voltage interface, the valve output voltage
value will be displayed in the area of temperature. Output range:0~10V.
Parameter Setting
Power Failure Memory
Under the shutdown state, press& hold
will enter interface for power failure memory
Selection, “PAGE” displays. Press
or
to change setting value, then press “M” to confirm and
return.
After power failure:
000 (default) indicates device will be in shutdown state (“OFF”) when power on again;
001 indicates device will be in working interface when power on again;
002 indicates device will stay the status before power failure when power on again.
Temp. Calibration/ Temp. Setting Range
Under the shutdown state, press & hold
will enter interface for temperature calibration,
“-ERR”displays. The calibration range is among -5.0 ~ +5.0
.
℃
Press
or
to change setting value, then press “M” save and enter interface for temp.
Range setting (0~99
):
℃
1. “-HI-” displays, the default value are 35
. Press
℃
or
can set the value;
2. Press “M” again, “-LO-”displays, the default value is 5
. Press
℃
or
can set the value;
3. Then press “M” to confirm and return to “OFF”.
Screen Brightness/ Fan continuously work/ Key-touch volume
Under the shutdown state, press & hold “M” will enter interface for screen brightness selection
(LED), Press
or
can choose: (press “M” to confirm the choice and enter into next setting)
111 indicates the screen will always be full bright when power on;
000 (default) indicates without button operation for a long time (15 seconds), the screen will be
half bright automatically.
Press “
M
” again will enter interface for Fan continuously work choice:
000 (default) indicates device will shutdown fan and valve if room temp. Reaches setting temp.;
001 indicates device will shutdown valve only if room temp. Reaches setting temp. The fan will
continuously work in low speed.
Press “M” again will enter interface for Key-touch volume (BEEP) setting:
0: Off 1: On
Temp. Sensor Error
If temperature sensor does not work, “E1” displays , fan stops and valve closes automatically.
Z-Wave Operation
Including & Excluding of Z-Wave network
Under the shutdown state, press & hold
to enter interface for inclusion or exclusion of
Z-Wave network. Before device included into network, “- - -” will display on the screen. Then
press
once, device will enter learning mode to get a node ID. If inclusion is success, a node ID will
display on the screen in a few seconds.