Page 31
1
5
6
9
Power, Alarm & IBS port (2m cable supplied)
Pin
Number
Connection
NAV-7
Cable Colour
Notes
1
IBS_TXA
O/P
WHITE/BLUE
O/P to IBS port
2
3
+V
(12/24 V DC nominal)
I/P
RED/BLUE
Ship’s ve
4
-V (0V)
I/P
BLUE/RED
Ship’s supply -ve
5
6
IBS_TXB
O/P
BLUE/WHITE
O/P to IBS port
7
8
AUX_NC
O/P
ORANGE/WHITE
Alarm Relay NC
9
AUX_NO
O/P
WHITE/BROWN
Alarm Relay NO
10
AUX_COM
O/P
WHITE/GREY
Alarm Relay COM
11
12
IBS_RXB
I/P
GREEN/WHITE
I/P from IBS port
13
IBS_RXA
I/P
WHITE/GREEN
I/P from IBS port
14
15
Connecting to the NMEA 0183 interface
If a connection to NMEA 0183 compatible equipment is
required then a suitable cable has to be purchased or
manufactured.
Recommended NMEA 0183 cable:
Two twisted pairs,
screened, PVC sheathed. For lengths to 200 meters, use
0.22 mm
2
(7/32); Belden 8102 or equivalent.
The connections to the D-Sub 9-pin socket on the NAV-7 are given below. Note that
the cable screen should not be connected to any part of the NAV-7.
NMEA 0183 & printer port
Pin Number
Connection
Notes
1
2
SER_TXB
O/P to NMEA 0183 (printer)
3
4
SER_RXB
I/P from NMEA 0183
5
6
7
SER_TXA
O/P to NMEA 0183 (printer)
8
SER_RXA
I/P from NMEA 0183
9