An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do  not place heavy objects  on the unit as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

     Contact your dealer as   to the  cleaning. If   dust is 
    allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

  If   dust  accumulates   on the  power supply plug or in
  the   wall   AC   outlet,  a   fire  may   result.  Clean  it 
  periodically. In  addition, insert   the  plug   in  the  wall 
  outlet securely.

  Switch  off t he  power, and unplug  the  power  supply
  plug   from the  AC outlet   for  safety   purposes  when 
  cleaning   or  leaving  the unit unused for  10  days  or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

 SAFETY PRECAUTIONS

4

Содержание MPA-120

Страница 1: ...SS SYSTEM MIC1 INPUT BASS TREBLE MIC2 TEL OUTPUT LEVEL 2 4 6 8 10 PROT POWER MIC1 AUX MASTER ON OFF 0 0 0 0 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 5 5 0 0 1 1 2 2 3 3 4 4 1 1 2 2 3 3 4 4 5 5 5 0 1 2 3 4 6 7 8 9 10 MIXER AMPLIFIER MPA 20 ON OFF MIC1 INPUT BASS TREBLE MIC1 MIC2 MIC3 AUX1 AUX2 TEL MASTER POWER 2 PROT TEMP 4 6 8 10 12 OUTPUT LEVEL MIXER AMP...

Страница 2: ...CTIONS 17 4 18 19 20 21 22 NOMENCLATURE AND FUNCTIONS 2 1 FRONT PANEL 2 2 REAR PANEL 3 MACHINE OPERATION 5 APPLICATIONS 6 BLOCK DIAGRAM 7 SPECIFICATIONS 8 DIMENSIONAL DIAGRAM MPA 60 MPA 120 NOMENCLATURE AND FUNCTIONS 2 1 FRONT PANEL 2 2 REAR PANEL 3 MACHINE OPERATION 5 APPLICATIONS 6 BLOCK DIAGRAM 7 SPECIFICATIONS 8 DIMENSIONAL DIAGRAM ...

Страница 3: ...result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in u...

Страница 4: ...ing sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched...

Страница 5: ...hms AUX input 4 1 channel MIC1 balanced unbalanced input 2 5 5mv 1 2Kohms 5 1 channel TEL input sensitivity 350mV 10Kohms 5 Aux is default signal MIC1 input will override MIC2 and Aux inputs Telephone input will override both MIC1 MIC2 and AUX inputs 7 Built in priority functions Priority level is as follows 6 Built in treble and bass adjustment bass 10dB 100Hz treble 10dB 10KHz ...

Страница 6: ...ORS Level meters 5 output level indicators 11 PROTECTION When the machine is in protection status this indicator will be lit in normal operation status the LED is off If the product is in protection status due to overheating overload or direct current the indication LED will be lit while the output relay will be disconnected Signal indicator is just used to indicate the use of input music signal I...

Страница 7: ... except TEL 15 MIC input with phantom power MIC1 input compatible of XLR and stereo connector 16 MIC 1 PHANTOM 48V Power switch 17 MIC 2 MIC input MIC2 input of Microphone 18 AUX input AUX for extra equipment input 19 Line output Connect to other audio processing equipments 20 TEL INPUT 7 12 13 14 15 16 18 19 20 17 LINE OUT AUX MIC 2 120V 60Hz 40W T2AL 250V MUTE MIC 1 XLR 6 30 INPUT BAL UNBAL 48V ...

Страница 8: ...0 245 70V LINE 3 1 SPEAKER CONNECTIONS 4 16 3 CONNECTIONS 70V 8 MPA 40 125 MPA 40 250 Balanced Connections Unbalanced Connections Tip Signal Sleeve Ground 3 2 The combination input accepts either XLR or 1 4 microphone plugs 1 4 sources can be either balanced or unbalanced as shown ...

Страница 9: ... The four output connectors only can choose two connectors work together If voltage is 70V 100V the speakers must be with transformer and make sure the total power wattage of speaker is 15 less than the power wattage of amplifier GUIDANCE OF EXCLUDING ERRORS No voice output in normal condition All the wires are connected well but no voice output Cause 1 No power or wrong plug connection 2 Fuse is ...

Страница 10: ...OUT R L COM AUDIO SOURCES LINK INPUTS XLR BAL 1 GND 2 HOT 3 COLD 1 2 3 1 2 3 OUTPUTS INPUTS POWER AMPLIFIER SPEAKERS LINE OUT AUX MIC 2 120V 60Hz 40W T2AL 250V MUTE MIC 1 XLR 6 30 INPUT BAL UNBAL 48V PHANTOM OUTPUTS COM 4 16 70V 100V TEL INPUT G ...

Страница 11: ...6 BLOCK DIAGRAM COMP COMP GAIN AMP GAIN AMP GAIN AMP POWER AMP GAIN AMP 11 ...

Страница 12: ...ne control Bass 100Hz Treble 10KHz Line Out Total harmonic distortion Cooling mode Power source Power consumption Net weight Dimensions mm 4 16 70V 100V MIC 66dB AUX 80dB 80Hz 16KHz 5mV 1Kohms 48VDC 350mV 10Kohms 10dB 1000mV 470ohms Less than 0 5 Air cooling 60W 276X245X70 4 5Kg MIC1 2 5mV 1Kohms AUX 350mV 10Kohms TEL 350mV 10Kohms Channel crosstalk Separation 50dB Muting function MIC1 prior to th...

Страница 13: ...0 0 1 1 2 2 3 3 4 4 1 1 2 2 3 3 4 4 5 5 5 0 1 2 3 4 6 7 8 9 10 MIXER AMPLIFIER MPA 20 LINE OUT AUX MIC 2 120V 60Hz 40W T2AL 250V MUTE MIC 1 XLR 6 30 INPUT BAL UNBAL 48V PHANTOM OUTPUTS COM 4 16 70V 100V TEL INPUT G MIC1 INPUT BASS TREBLE MIC2 TEL OUTPUT LEVEL 2 4 6 8 10 PROT POWER MIC1 AUX MASTER ON OFF 0 0 0 0 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 5 5...

Страница 14: ...t and power fluctuation for optimum reliability 5 VOX feature mutes AUX inputs when input is detected on MIC 1 Time Adjust control allows resumption of music to be sharp or gradual 6 Phantom power available on MIC 1 input for condenser type microphones 14 Aux is default signal MIC1 input will override MIC2 MIC3 and Aux inputs Telephone input will override MIC1 MIC2 MIC3 and AUX inputs 8 Built in p...

Страница 15: ...TIONS 9 POWER Power indicator 10 LEVEL INDICATORS Level meters 6 output level indicators 11 PROTECTION 12 TEMP Temperature Indicator When the machine is in protection status this indicator will be lit in normal operation status the LED is off If the product is in protection status due to overheating overload or direct current the indication LED will be lit while the output relay will be disconnect...

Страница 16: ... phantom power MIC1 input compatible of XLR and 6 3 MIC 17 Phantom power switch 18 MIC 2 MIC 3 MIC input MIC2 3 input of 6 3 MIC 19 TEL INPUT 20 AUX 1 AUX 2 AUX input AUX 2 3 for extra equipment input 21 Line output Connect to other audio processing equipments 16 14 13 15 16 18 19 20 21 17 120V 60Hz 100W T3 15AL 250V MIC2 MIC3 MUTE G TEL INPUT AUX2 AUX1 LINE OUT MIC 1 XLR 6 30 INPUT BAL UNBAL PHAN...

Страница 17: ...0 81 70V LINE 3 1 SPEAKER CONNECTIONS 4 16 3 CONNECTIONS 70V 17 MPA 120 41 MPA 120 83 Balanced Connections Unbalanced Connections Tip Signal Sleeve Ground 3 2 The combination input accepts either XLR or 1 4 microphone plugs 1 4 sources can be either balanced or unbalanced as shown ...

Страница 18: ...The four output connectors only can choose two connectors work together If voltage is 70V 100V the speakers must be with transformer and make sure the total power wattage of speaker is 15 less than the power wattage of amplifier GUIDANCE OF EXCLUDING ERRORS No voice output in normal condition All the wires are connected well but no voice output Cause 1 No power or wrong plug connection 2 Fuse is b...

Страница 19: ...XLR BAL 1 GND 2 HOT 3 COLD 1 2 3 1 2 3 OUTPUTS INPUTS POWER AMPLIFIER SPEAKERS MIC 2 MIC1 MIC 3 TEL INPUT 120V 60Hz 100W T3 15AL 250V MIC2 MIC3 MUTE G TEL INPUT AUX2 AUX1 LINE OUT MIC 1 XLR 6 30 INPUT BAL UNBAL PHANTOM OUTPUTS COM 4 16 70V 100V COM COM www mcmelectronics com ...

Страница 20: ...6 BLOCK DIAGRAM 70V COM 4 TO PA BASS TREBLE VOLUME PROTECT LEVEL INDICATOR POWER Z 120V 60Hz PT COM 100V COM EB EB LINE OUT MIC1 MIC1 MIC2 MIC3 AUX1 AUX2 TEL MUTE MUTE 20 ...

Страница 21: ...wer AUX 1 input section AUX in 1Khz preamp out Input sensitivity impedance S N Frequency Response 3dB Tone control Bass 100KHz Treble 10KHz Pre Amp Out Total harmonic distortion Line level output Cooling mode Power source Power consumption Net weight Dimensions mm 4 16 70V 100V MIC1 2 3 5mV 600ohms AUX 350mV 10Kohms Better than 90dB 50Hz 18KHz 5mV 600ohms Better than 62dB 12dB 48VDC 350mV 10Kohms ...

Страница 22: ...ER 2 PROT TEMP 4 6 8 10 12 OUTPUT LEVEL MIXER AMPLIFIER MPA 60 120V 60Hz 100W T3 15AL 250V MIC2 MIC3 MUTE G TEL INPUT AUX2 AUX1 LINE OUT MIC 1 XLR 6 30 INPUT BAL UNBAL PHANTOM OUTPUTS COM 4 16 70V 100V COM COM www mcmelectronics com ON OFF MIC1 INPUT BASS TREBLE MIC1 MIC2 MIC3 AUX1 AUX2 TEL MASTER POWER 2 PROT TEMP 4 6 8 10 12 OUTPUT LEVEL MIXER AMPLIFIER MPA 60 ...

Страница 23: ...date of purchase This warranty is limited to manufacturer defects in either materials or workmanship MCM Electronics or any other worldwide divisions of Premier Farnell PLC are not responsible for any consequential or inconsequential damage to any other component structure or the cost of installation or removal of said items For questions or specific information regarding warranty replacement or r...

Отзывы: