4
Place the A-frame in the earth parallel along the path of the cable.
The Receiver will display an arrow on the LCD.
Arrow will point towards the red or blue indicator.
The A-frame legs will be marked with a red or blue decal.
Follow the direction the
Receiver is showing (Example – if the LCD is pointing towards
the red indicator and the red leg of the A-frame is pointing towards the front – walk
forward.)
Walk in this direction placing the A-frame in the earth every five to ten feet.
Note: If LCD does not display arrow or signal strength A-frame is not reading signal.
The A-frame may not be making contact with earth or signal is too weak due the distance
from the fault point or cable path. Continue walking the cable path. When the A-frame
begins to read signal the arrows and numbers will be displayed again.
When the arrow changes directions the operator has passed the fault.
Fault
Fault
Pointed the Red
indicator
Red decal
Pointed the blue
indicator
Blue decal
Cable Path
Ground
Stake
Meter
Transformer
Transmitter
Cable Path
Ground
Stake
Meter
Transformer
Transmitter
Содержание VISION FLX2