KP03 Mini Apartment Compactor
LOCKOUT/TAGOUT
27
Copyright
©
7/2021 K-PAC
™
Compactors, a product of McLaughlin Family Companies
All Rights Reserved
Figure 4
• Stored or residual hydraulic pressure must be relieved after blocking devices are installed. Locate the
direct acting directional control valve
on the Power Pack.
• Both solenoids
(Figure 4, 2)
on the directional valve have a manual override.
• Insert an 1/8" or less diameter pin or screw driver
(Figure 4, 3)
into the end of both solenoid spools to
relieve hydraulic pressure from both hydraulic lines for the ram cylinders.
• Disable the Power Pack by turning the ON-OFF switch
to OFF on the control panel. Remove
the key and keep in your possession.
Figure 5
• After applying LOCKOUT/TAGOUT to system, verify the system has been isolated and disconnected from
the energy source.
• First check that no personnel are exposed.
• Operate the controls to verify they have been disabled.
The compactor is now in LOCKOUT/TAGOUT.
2
3
2
1
2
1