Use the remaining 9 menu names to access the timer and cycle settings. The following menu names can be
selected using the navigation buttons
to select.
EXTEND MENU
- The Extend menu
is the
first menu to appear. The menu sets the time the ram cyl-
inders will extend. To change the time, press the OK but-
ton
and a cursor should appear on the
extend time box
. Use the Up and Down
navigation buttons
to increase or decrease
the time. The left or right arrows will allow you to make
finer adjustments in tenths and hundredths of a second.
The default setting is 10 seconds. After the desired time
is obtained, press the OK button again to accept settings.
All of the following timers and counters are adjusted in
the same manner as previously described. The order in
which they are described will correspond with the use of
the Down navigation button.
Figure 36
RETRACT MENU
- The Retract menu
sets the time the ram cylinders will retract. The default
setting is 6.04 seconds
. After the desired
time is obtained, press the OK button
again to accept settings.
Figure 37
MENU
DESCRIPTION
EXTEND
Controls the time the ram cylinders will extend. The default setting is 10 seconds.
RETRACT
Controls the time the ram cylinders will retract. The default setting is 6.04 seconds.
AUTO C
Controls the number of cycles that the unit will complete when you depress the start
button or the photo-eye is tripped. The default setting is 3 cycles.
80% CNT
Controls when the 80% light comes ON. The default setting is 5.
80% LITE
Is the timer that controls the time the signal is received before it is sent to the 80% CNT.
The default setting is 5 seconds.
100% CNT
Controls when the 100% light comes ON. The default setting is 6.
100% LIT
Is the timer that controls the time the signal is received before it is sent to the 100% CNT.
The default setting is 6.05 seconds.
P-EYE
The function will shut down the compactor if the photo-eye becomes blocked for more
than a period time. The default setting is 5 minutes.
P-DELAY
Time the compactor will delay the auto-cycle if triggered by the optional photo-eye.
4