McIntosh MQ108 Скачать руководство пользователя страница 4

IMPORTANT 

SAFETY 

INSTRUCTIONS 

THESE 

INSTRUCTIONS 

ARE TO PROTECT 

YOU AND THE 

MclNTOSH 

INSTRUMENT. 

BE SURE TO 

FAMILIARIZE 

YOURSELF 

WITH THEM 

Copyright 1993 © by 

Mclntosh Laboratory Inc. 

1. Read all instructions - Read the safety and operating instructions before operating the instrument. 
2. Retain Instructions - Retain the safety and operating instructions for future reference. 
3. Heed warnings - Adhere to warnings and operating instructions. 
4. Follow Instructions - Follow all operating and use instructions. 

W A R N

I

N G :

 TO  R E D U C E RISK  O F FIRE  O R ELECTRICAL  S H O C K ,  D O NOT EXPOSE  T H I S IN-

S T R U M E N T  T O  R A I N  O R  M O I S T U R E . 

5. Power Sources - Connect the power supply only to the type described in the operating instructions 

or as marked on the unit. 

6. Power-Cord Protection - Route power-supply cords so that they are not likely to be walked on or 

pinched by items placed upon or against them, paying particular attention to cords at plugs, 
convenience receptacles, and the point where they exit from the instrument. 

7. Ventilation - Locate the instrument for proper ventilation. For example, the instrument should not 

be placed on a bed, sofa, rug, or similar surface that may block ventilation openings; or, placed 

in a built-in installation, such as a bookcase or cabinet, that may impede the flow of air through 

the ventilation openings. 

8. Heat - Locate the instrument away from heat sources such as radiators, heat registers, stoves, or 

other appliance (including amplifiers) that produce heat. 

9. Wall or Cabinet Mounting - Mount the instrument in a wall or cabinet only as described in the owner's 

manual. 

10. Water and Moisture - Do not use the instrument near water - for example, near a bathtub, washbowl, 

kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc. 

11. Cleaning - Clean the instrument by dusting with a dry cloth. Clean the panel with a cloth moistened 

with a window cleaner. 

12. Object and Liquid Entry - Do not permit objects to fall and liquids to spill into the instrument through 

enclosure openings. 

13. Nonuse Periods - Unplug the power cord from the AC power outlet when left unused for a long period 

of time. 

14. Damage Requiring Service -

 Service must be performed by qualified service personnel when: 

A. The power supply cord or the plug has been damaged; or 

B. Objects have fallen, or liquid has been spilled into the instrument; or 

C. The instrument has been exposed to rain; or 

D. The instrument does not appear to operate normally or exhibits a marked change in performance; 

or 

E. The instrument has been dropped, or the enclosure damaged. 

15. Servicing - Do not attempt to service beyond that described in the operating instructions. All other 

service should be referred to qualified service personnel. 

16. Grounding or Polarization - Do not defeat the inherent design features of the polarized plug. Non-

polarized line cord adaptors will defeat the safety provided by the polarized AC plug. 

17.

 CAUTION:

 TO PREVENT ELECTRICAL SHOCK DO NOT USE THIS (POLARIZED) PLUG 

WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN 

BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. 

ATTENTION:

 POUR PREVENIR LES

 CHOCS ELECTRIQUES PAS UTILISER CETTE 

FICHE POLARISEE AVEC UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE 

SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN 

LAISSER AUCUNE PARTIE A DECOUVERT. 

The lightning flash with arrowhead, within an equilateral triangle, is intended to alert the 

user to the presence of uninsulated "dangerous voltage" within the product's enclosure 
that may be of sufficient magnitude to constitute a risk of electric shock to persons. 

CAUTION:

 TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT 

REMOVE COVER (OR BACK). NO USER-SERVICABLE PARTS INSIDE. 
REFER SERVICING TO QUALIFIED PERSONNEL. 

The exclamation point within an equilateral triangle is intended to alert the user to the 

presence of important operating and maintenance (servicing) instructions in the literature 
accompanying the appliance. 

WARNING: THIS UNIT IS CAPABLE OF PRODUCING HIGH SOUND 

PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND 
PRESSURE LEVELS CAN CAUSE PERMANENT HEARING IMPAIRMENT 

OR LOSS. USER CAUTION IS ADVISED AND EAR PROTECTION IS 

RECOMMENDED WHEN PLAYING AT HIGH VOLUMES. 

Содержание MQ108

Страница 1: ...MQ108 CUSTOM ENVIRONMENTAL EQUALIZER...

Страница 2: ......

Страница 3: ...MQ108 CUSTOM ENVIRONMENTAL EQUALIZER...

Страница 4: ...s 13 Nonuse Periods Unplug the power cord from the AC power outlet when left unused for a long period of time 14 Damage Requiring Service Service must be performed by qualified service personnel when...

Страница 5: ...t it will become a highly valued part of your home music system SERVICE CONTRACT 4 INTRODUCTION 5 ROOM ACOUSTICS 5 6 EQUALIZING FOR OPTIMUM LISTENING 6 7 HOW TO CONNECT 7 MEASURING THE ROOM ACOUSTICS...

Страница 6: ...of the service contract the ser vice contract certificate must accompany the instrument when taken to the service agency 3 Always have service done by a Mclntosh authorized service agency If the instr...

Страница 7: ...ceiling covering The stiffness or flexibility of the room surfaces Reflections from furniture or substructures in the room All these factors can affect the sound balance Standing waves or room resonan...

Страница 8: ...th the output from the Near microphones to add a desired degree of liveness and realism to the recording Concert hall acoustics will modify live sound and cause a gradual rolloff in high frequen cies...

Страница 9: ...r similar analyzer will be satisfactory The analyzer microphone should be located in the listening area at normal ear height Measurements should be made for each stereo channel separately The results...

Страница 10: ...l is turned clockwise the filter boosts When the control is turned counterclockwise the filter cuts Capacitors A and B program the frequency and bandwidth of the filter Capacitor values are determined...

Страница 11: ...with the analyzer If you are using an analyzer with a continuous display the controls may be adjusted and results seen immediately If you are using an analyzer that indicates with a meter the controls...

Страница 12: ...WEIGHTED 105dB below rated output 95dB IHF MAXIMUM INPUT SIGNAL High level 8V INPUT IMPEDANCE 22 000 ohms HIGH FREQUENCY COMPENSATION 10dB at 20 000Hz PROGRAMMABLE FILTERS 14 sections 7 per channel ea...

Страница 13: ...TZ 10000 20000 Response in dB 20 10 1 0 2 0 20 FREQUENCY IN HERTZ 10000 20000 11 RESPONSE CURVES 1000 TYPICAL FILTER RESPONSE CHARACTERISTICS 200 Hertz Filters Shown TWO NARROW CASCADED NARROW WIDE HI...

Страница 14: ...60 50 LEFT SPEAKER Suggested Equalization Curves 12 BAND FREQUENCY IN Hz 20 25 31 5 40 50 63 80 100 126 160 200 250 315 400 500 630 800 1k 1 25k 1 6k 2k 2 5k 3 15k 4k 5k 6 3k 8k 10k 12 5k 16k 20k 70...

Страница 15: ...USE FOR CHARTING LOUDSPEAKER TESTS SPL IN dB 90 80 70 60 50 RIGHT SPEAKER SPL IN dB 80 70 60 50 13 GRAPHS 90 LEFT SPEAKER...

Страница 16: ...USE FOR CHARTING LOUDSPEAKER TESTS L E F T SPEAKER 80 SPL IN dB 70 60 50 RIGHT SPEAKER SPL IN dB 80 70 60 50 14 GRAPHS 90 90...

Страница 17: ......

Страница 18: ...04012400...

Страница 19: ......

Страница 20: ......

Отзывы: