5
Installation
Installation
The MI347 may be placed upright on its four feet
or custom installed with the four feet removed. If
removed, retain the four feet and fastening screws for
any future re-installation. The panel cutout, ventilation
cutout and unit dimensions are shown in the drawing
on the right side of this page.
It is necessary to provide adequate ventilation for
cool operation, ensuring long life for the MI347. Do
not install the MI347 above heat generating compo-
nents. When the MI347 is installed in a cabinet with
other components, a ventilation fan may be added to
provide cool operating temperature.
A custom cabinet installation needs to provide the
following minimum spacing for cool operation:
Allow at least 3 inches (7.6cm) above the top,
2 inches (5.08cm) below the bottom, 3 inches
(7.62cm) behind the rear panel and 2 inches
(5.08cm) on each side of the MI347, providing
airflow. Allow 2-1/2 inches (6.4cm) in front of the
mounting
1
panel for clearance. Be sure to cut out a
ventilation hole in the mounting shelf according to
the dimensions in the drawing.
1
When the MI347 is installed together with other
McIntosh Components, check clearances on all
components before proceeding.
Installation of Side Rack Mount Brackets
When desired, to install MI347 Side Rack Mounting
Brackets, follow the steps below for one side at a time:
1. Refer to figure A to remove the two side screws and
save them for possible future use.
2. Position the Side Rack Mounting Bracket as illustrated
in figure B. Then attach the Bracket to the Front and
Side Panel of the MI347, using the screws supplied
with the Bracket.
3. Perform steps 1 and 2 to mount the second Bracket to
the other side of the MI347.
Support Shelf
MI347 Bottom View
in Custom Cabinet
Note: Center the cutout Horizontally
on the unit. For purposes of
clarity, the above illustration
is not drawn to scale.
1
1/8
"
2.9cm
15/32
"
1.2cm
5.7cm
12-
3/8
"
31.4cm
15
40.3cm
Cutout Opening
for Ventilation
14-
1/4
"
36.2cm
15-
1/2
"
39.4cm
Remove two
Screws from
the Chassis
Sidewall
and save
them
Front Panel
Side Panel
Figure A
Figure B
Side Rack
Mounting
Bracket
Supplied
Screws
Front Panel
Side Panel
Supplied
Screws
Chassis Spacers
Cutout Opening for Ventilation
7/8
"
2
1/4
"
MI347 SEVEN CHANNEL
POWER AMPLIFIER
POWER
Cutout Opening for Custom Mounting
MI347 Front Panel
Custom Cabinet Cutout
MI347 Side View
in Custom Cabinet
Cabinet
Front
Panel
Opening
for Ventilation
16-
7/8
"
42.9cm
5-
1/4
”
13.4cm
3"
7.6cm
4
5
L
C
R
6