background image

9

•  Rotate the end of the Output Terminal Post 

counterclockwise until an opening appears 

(Figure 08)

•  Remove the two Cover Screws from the rear 

of the MC901. These will be used to secure 

the Terminal Connection Cover (Figure 10 on 

page 9). The Terminal Connection Covers 

ship unsecured and the screws are in place

•  Insert the Loudspeaker Hookup Cable through 

the Cover Opening of the Output Terminal 

Cover (Figure 11). Choose the opening that 

will be closest to the Output Terminal Posts 

you will be connecting

•  Insert the Loudspeaker hookup cable into the 

Output Terminal Post opening or the cable 

spade lug around the center post of the Output 

Terminal (Figure 08)

•  Rotate the end of the Output Terminal Post 

clockwise until it is finger tight

•  Place the supplied McIntosh wrench over 

the end of the Output Terminal and rotate 

it one quarter of a turn (90°) to secure the 

Loudspeaker cable connection (Figure 09).  

Do not over tighten

•  Slide the Terminal Connection Cover over the 

Output Terminals. Fasten with the two screws 

removed earlier

WARNING: 

Loudspeaker terminals are hazardous 

live and present a risk of electric shock. Make sure the 

Terminal Connection Cover is installed. For additional 

instructions on making Loudspeaker connections 

contact your McIntosh Dealer or McIntosh Technical 

Support.

Remove Loudspeaker Jumpers

IMPORTANT: Never combine the Solid State and 

Vacuum Outputs of the MC901.

If the Loudspeaker’s Terminals connected to the Solid 

State Outputs of the MC901 are connected via jumper 

cables to the Loudspeaker Terminals connected to 

the MC901’s Vacuum Outputs, 

REMOVE THE 

JUMPER CABLES.

  

If the Vacuum Tube Output is powering both 

Midrange and High terminals of the Loudspeaker, and 

the Solid State Output is powering the Low Terminals, 

jumper cables can be used to connect the High and 

Midrange Terminals.  

120V     50/60Hz

12 AMPS

CIRCUIT

BREAKER

Cover Screws

Cover Screws

Figure 10–  Terminal Connection Covers

Opening

Figure 08–  Opening Output Terminal

Figure 09–  Tightening Output Terminal 

Figure 11–  Terminal Connection Cover openings

Cover Openings 

Содержание MC901

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MC901 Dual Mono Amplifier Owner s Manual...

Страница 2: ...ompromising tube and solid state Amplifiers The MC901 combines the finest aspects of tube and solid state Amplifiers to drive even the most power hungry Loudspeakers to peak performance Safety First P...

Страница 3: ...15 Vacuum Tube Positions 13 Figure 16 Dual Meter 13 Figure 17 Front Knobs and LEDs 14 Figure 18 Roll Off for Low Pass Filter 16 Figure 19 Roll Off for High Pass Filter 17 Figure 20 1K Roll off Combin...

Страница 4: ...State side the MC901 utilizes our Autoformer which provides the optimal method of connecting a Solid State Amplifier to a Loudspeaker of virtually any impedance The McIntosh Autoformer provides full p...

Страница 5: ...VACUUM TUBES PRIOR TO CONNECTING THE A C POWER SUPPLY CORD To prevent damage to the Tubes during shipping there are special foam inserts surrounding the Tubes of the Power Amplifier The Foam Inserts m...

Страница 6: ...er Wire from a Loudspeaker to the Solid State Amplifier Positive and Negative terminals for 2 4 and 8 Ohm connections VACUUM TUBE INPUT SELECT Switch Used to select DIRECT or COMPOSITE input for the V...

Страница 7: ...The SOLID STATE INPUT SELECT is located below the SOLID STATE DIRECT INPUT Select either DIRECT or COMPOSITE With the COMPOSITE INPUT selection signal will flow through the Level Adjust and the Low P...

Страница 8: ...onnection Each Amplifier has a pair of 2 Ohm 4 Ohm and 8 Ohm Output terminals Keep in mind that the impedance rating of your Loudspeaker is an average over a range of frequencies It would be helpful i...

Страница 9: ...he Terminal Connection Cover over the Output Terminals Fasten with the two screws removed earlier WARNING Loudspeaker terminals are hazardous live and present a risk of electric shock Make sure the Te...

Страница 10: ...downside is that each transistor added raises the noise floor a small amount Quad Balancing eliminates this problem In the MC901 the 600 watt Solid State Amplifier contains two identical signal paths...

Страница 11: ...2 AMPS CIRCUIT BREAKER Figure 13 MC901 Connection Diagram Connection 1 Balanced cable Preamplifier to Composite Input 2 Balanced cable to 2nd MC901 3 Power Control from Preamplifier OUT to IN 4 Power...

Страница 12: ...nob is continuous so all settings between 100Hz and 1kHz are available The HIGH PASS FILTER will not amplify frequencies below the roll off point of the HIGH PASS FILTER It is possible to set each fil...

Страница 13: ...Dual Meter which displays the power output for both the Vacuum Tube and Solid State Amplifiers The Vacuum Tube scale is displayed on the top and the longer needle will point to the current output The...

Страница 14: ...fier or A V Control Figure 17 Front Knobs and LEDs Power Guard Screen Grid Sensor LED Power Guard LED Meter Control Knob Power Control Knob Center connected by a Power Control Cable See Power Control...

Страница 15: ...is very important that the four plastic feet are attached to the bottom of the equipment The feet come installed on the MC901 The feet ensure the proper equipment location on the bottom pad Failure t...

Страница 16: ...over settings The output will taper starting with the selected CROSSOVER POINT Figure 18 Roll Off for Low Pass Filter The lines from left to right represent the Crossover Points as noted on the SOLID...

Страница 17: ...r High Pass Filter Frequency Hz Decibels The lines from left to right represent the Crossover Points as noted on the VACUUM TUBE HIGH PASS FILTER Knob 100 A 130 B 180 C 250 D 300 E 400 F 550 G 800 H 1...

Страница 18: ...oll off Combined Graph Roll off for 1K Crossover Point This graph uses a 1k CROSSOVER POINT for both Filters This demonstrates the combined taper for both the HIGH PASS and LOW PASS Filters Other CROS...

Страница 19: ...to 20 000Hz 0 3 0dB from 10Hz to 70 000Hz Total Harmonic Distortion 0 5 maximum harmonic distortion at any power level from 250 milliwatts to rated power 20Hz to 20 000Hz Intermodulation Distortion 0...

Страница 20: ...s is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcinto...

Отзывы: