How to Connect the MC162

To AC Outlet

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

Left Loudspeaker

4ohm

1. Connect the MC162 power cord to a live AC outlet.

2. Connect a power control cable from the control center

Power Control Out to the MC162 Power Control In.

3. Connect the loudspeaker cables to the appropriate ter-

minals for your loudspeakers, being careful to observe

the correct polarities.

NOTE: To prevent the possibility

of user contact with

potentially dangerous

voltages, install the

protective cover(s) over

the loudspeaker output

terminals after the

loudspeaker cables have

been connected. The

covers and cover

mounting screws are

located in an accessory package that is enclosed in the

amplifier shipping carton. There are two types of

How to Connect the MC162

McIntosh C38 System Control Center

screws in the package. Install the protective covers

with the Phillips, 6-32 by 5/16 inch self tapping screws.

The other screws are No. 6 by ½ inch wood screws

used to secure the amplifier custom mounting brackets

to a shelf.

4. Connect a cable from the unbalanced outputs of a con-

trol center to the MC162 unbalanced Input connectors

for both audio channels and power control.

Note: An optional hookup is to use balanced cables from a

McIntosh Control Center to inputs of the MC162.

Pin configuration for the XLR Balanced Input

connectors on the MC162:

PIN 1: Shield or ground.

PIN 2: + input.

PIN 3: - input.

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

123456789

Right Loudspeaker

4ohm

Содержание MC162

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton NewYork 13903 2699 Phone 607 723 3512 FAX 607 724 0549 OWNER S MANUAL MC162 MC162 Power Amplifier...

Страница 2: ...y Inc Thank You Please Take A Moment Customer Service and Table of Contents Thank You Please Take A Moment The serial number purchase date and McIntosh dealer name are important to you for possible in...

Страница 3: ...at may impede the flow of air through the ventilation openings 10 Locate the equipment away from heat sources such as radiators heat registers stoves or other appliance in cluding amplifiers that prod...

Страница 4: ...ence receptacles as this can result in a risk of fire or electric shock Care of Equipment 18 Clean the instrument by dusting with a dry cloth Un plug this equipment from the wall outlet and clean the...

Страница 5: ...hes 53 3cm depth behind the mounting panel which includes clearance for connectors Allow 1 1 8 inches 2 9cm in front of the mounting panel for knob clearance Be sure to cut out a ventilation hole in t...

Страница 6: ...OWER CONTROL IN receives turn on off sig nals from a McIntosh component and the POWER CONTROL OUT sends that turn on off signal to the next McIntosh component UNBALANCED INPUTs for audio cables from a...

Страница 7: ...ews are located in an accessory package that is enclosed in the amplifier shipping carton There are two types of How to Connect the MC162 McIntosh C38 System Control Center screws in the package Insta...

Страница 8: ...trols METERS indicate power output of the amplifier channels METER Switch selects the display modes of the power output meters POWER GUARD LED s light when the amplifier channel POWER GUARD circuit ac...

Страница 9: ...mplifier channel Hold The meter pointer is locked to the highest power peak in a sequence of peaks The meter is electronically held to this power level until another higher power peak passes through t...

Страница 10: ...oes not exceed twice the rated output with both channels operating for any combination of frequencies from 20Hz to 20 000Hz Signal To Noise Ratio 110dB below rated output Sensitivity 9 volts 2 0V at l...

Страница 11: ...arton and interior parts only if they are all in good serviceable condition If a shipping car ton or any of the interior part s are needed please call or write Customer Service Department of McIntosh...

Страница 12: ...McIntosh Part No 04054901 McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903...

Отзывы: