background image

10

Specifications

Specifications

Power Output Per Channel

120 watts into 4 ohm or 80 watts into 8 ohm loads is the

minimum sine wave continuous average power output per

channel both channels operating.

Output Load Impedance

4 or 8 ohms

Rated Power Band

20Hz to 20,000Hz

Dynamic Headroom

1.6dB

Frequency Response

+0, -0.25dB from 20Hz to 20,000Hz

+0, -3dB from 10Hz to 100,000Hz

Total Harmonic Distortion

0.005% maximum at any power level from 250 milliwatts

to rated power per channel from 20Hz to 20,000Hz, both

channels operating.

Intermodulation Distortion

0.005% maximum if instantaneous peak output per channel

does not exceed twice the rated output with both channels

operating for any combination of frequencies from 20Hz to

20,000Hz.

Signal To Noise Ratio

110dB below rated output

Sensitivity

.8 volts (2.5V at the marked position)

Input Impedance

10,000 ohms

Damping Factor

Greater than 100 at 4 ohms

Greater than 200 at 8 ohms

Power Requirements

100 Volts, 50/60Hz at 3.4 amps

110 Volts, 50/60Hz at 3.1 amps

120 Volts, 50/60Hz at 2.8 amps

220 Volts, 50/60Hz at 1.5 amps

230 Volts, 50/60Hz at 1.5 amps

240 Volts, 50/60Hz at 1.4 amps

NOTE: Refer to the rear panel of the MC122 for the correct

voltage

Dimensions

17-1/2 inches (44.5cm) wide, 3-5/8 inches (9.2cm) high,

17-1/2 inches (44.5cm) deep, including clearance for con-

nectors. Allow 3/4 inches (1.9cm) in front of the mounting

panel for clearance.

Weight

24 pounds (10.9 Kg) net, 39 pounds (17.7 Kg) in shipping

carton

Содержание MC122

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton NewYork 13903 2699 Phone 607 723 3512 FAX 607 724 0549 OWNER S MANUAL MC122 MC122 Power Amplifier...

Страница 2: ...Inc Thank You Please Take A Moment Customer Service and Table of Contents Thank You Please Take A Moment The serial number purchase date and McIntosh dealer name are important to you for possible ins...

Страница 3: ...courant ou un autre sortie de courant sauf si les lames peuvent etre inserees afond ans en laisser aucune partie a decouvert 7 For added protection for this product during a lightning storm or when i...

Страница 4: ...e or electric shock Care of Equipment 18 Clean the instrument by dusting with a dry cloth Un plug this equipment from the wall outlet and clean the panel with a cloth moistened with a window cleaner D...

Страница 5: ...llow at least 1 1 2 inches 3 8cm above the unit so airflow is not obstructed Allow 17 1 2 inches 44 5cm depth behind the mounting panel which includes clearance for connec tors Allow 1 1 8 inches 2 9c...

Страница 6: ...IN receives turn on off sig nals from a McIntosh component and the POWER CONTROL OUT sends that turn on off signal to the next McIntosh component INPUTs for audio cables from a preamplifier or control...

Страница 7: ...ontrol Out to the MC122 Power Control In 3 Connect the loudspeaker cables to the appropriate ter minals for your loudspeakers being careful to observe the correct polarities 4 Connect a cable from the...

Страница 8: ...Panel Displays and Switch MC122 Front Panel Displays and Switch POWER GUARD LED s light when the amplifier channel POWER GUARD circuit activates POWER Switch Turns AC power on off or on remote Power...

Страница 9: ...fer to Figure 1 Power On The MC122 power switch operates in two different modes When the MC122 Power Control In jack is connected to the Power Control Out jack of a McIntosh Control Center Preamplifie...

Страница 10: ...wice the rated output with both channels operating for any combination of frequencies from 20Hz to 20 000Hz Signal To Noise Ratio 110dB below rated output Sensitivity 8 volts 2 5V at the marked positi...

Страница 11: ...hipping carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Customer Service Department of M...

Страница 12: ...McIntosh Part No 040584 McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903...

Отзывы: