The lightning flash with arrowhead, within an equilateral 

triangle, is intended to alert the user to the presence of 

uninsulated “dangerous voltage” within the product’s en-

closure that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 

intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in the 

literature accompanying the appliance.

WARNING - TO REDUCE RISK 

OF FIRE OR ELECTRICAL 

SHOCK, DO NOT EXPOSE 

THIS EQUIPMENT TO RAIN OR 

MOISTURE.

NO USER-SERVICEABLE PARTS 

INSIDE. REFER SERVICING TO 

QUALIFIED PERSONNEL.

To prevent the risk of electric 

shock, do not remove cover or 

back. No user-serviceable parts 

inside.

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with a dry cloth.

7. Do not block any ventilation openings. Install 

in accordance with the manufacturer’s instruc-

tions.

8. Do not install near any heat sources such as 

radiators, heat registers, stoves, or other appa-

ratus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polar-

ized or grounding-type plug. A polarized plug 

has two blades with one wider than the other. 

A grounding type plug has two blades and a 

third grounding prong. The wide blade or the 

third prong are provided for your safety. If 

the provided plug does not fit into your outlet, 

consult an electrician for replacement of the 

obsolete outlet.

10. Protect the power cord from being walked on 

or pinched particularly at plugs, convenience 

receptacles, and the point where they exit 

from the apparatus.

11. Only use attachments/accessories specified by 

the manufacturer.

12. Use only with the cart, stand, tripod, bracket, 

or table specified by the manu

-

facturer, or sold with the appa-

ratus. When a cart is used, use 

caution when moving the cart/

apparatus combination to avoid 

injury from tip-over.

13. Unplug this apparatus during lightning storms 

or when unused for long periods of time.

14. Refer all servicing to qualified service person

-

nel. Servicing is required when the apparatus 

has been damaged in any way, such as power-

supply cord or plug is damaged, liquid has 

been spilled or objects have fallen into the 

apparatus, the apparatus has been exposed to 

rain or moisture, does not operate normally, or 

has been dropped.

15. Do not expose this equipment to dripping or 

splashing and ensure that no objects filled 

with liquids, such as vases, are placed on the 

equipment.

16. To completely disconnect this equipment from 

the a.c. mains, disconnect the power supply 

cord plug from the a.c. receptacle.

17. The mains plug of the power supply cord shall 

remain readily operable.

18. Do not expose batteries to excessive heat such 

as sunshine, fire or the like.

19. Connect mains power supply cord only to a 

mains socket outlet with a protective earthing 

connection.

IMPORTANT SAFETY 

INSTRUCTIONS!

PLEASE READ THEM BEFORE 

OPERATING THIS EQUIPMENT.

Содержание D100

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com D100 Digital Preamplifier Owner s Manual ...

Страница 2: ...ed for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or...

Страница 3: ...our Dealer You can also return it to the McIntosh Laboratory Service Department For assistance on factory repair return procedure contact the McIntosh Service Department at McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 Phone 607 723 3515 Fax 607 723 1917 The serial number purchase date and McIntosh Dealer name are important to you for possible insurance claim or future servic...

Страница 4: ...s Batteries should never be thrown away or incinerated but disposed of in accordance with the local regulations concerning battery disposal 7 For additional information on the D100 and other McIntosh Products please visit the McIntosh Web Site at www mcintoshlabs com General Information and Connector Information Connector and Cable Information XLR Connectors Below is the Pin configuration for the ...

Страница 5: ...l sources Balanced Outputs The Balanced Outputs allow the connection of long cable lengths without a loss in sound quality Precision Tracking Volume Control Volume levels are controlled by a new Precision Digi tally Controlled Attenuator System with a tracking accuracy of 0 1dB Alphanumeric Fluorescent Display The Front Panel Information Display indicates the Source Selection Sampling Frequency Bi...

Страница 6: ...on the next page pertaining to installing the D100 into cabinets Rear View of the D100 Side View of the D100 Front View of the D100 17 1 2 44 5cm 2 17 32 6 4cm 3 9 32 8 3cm 3 7 8 9 8cm 17 1 32 43 3cm 2 11 32 6 0cm 13 1 4 33 7cm 13 33 0cm 12 1 16 30 6cm 1 1 6 2 7cm 1 5 8 4 1cm 29 32 1 8cm 9 1 16 23 0cm 1 3 8 3 5cm 2 11 32 6 0cm 5 USB 192 24 ...

Страница 7: ...maintaining all the system components at the coolest possible operating temperature A custom cabinet installation should provide the following minimum spacing dimensions for cool operation Allow at least 2 inches 5 08cm above the top 2 inches 5 08cm below the bottom and 1 inch 2 54cm on each side of the Preamplifier so that airflow is not obstructed Allow 15 inches 38 1cm depth behind the front pa...

Страница 8: ... IR INput for signals from a compatible IR Room Sensor POWER CONTROL IN receives turn on signals from a McIntosh component POWER CONTROL OUT sends turn on signals on to another McIn tosh Component DATA IN receives control data from a McIntosh Preamplifier or A V Control Center FIXED AUDIO OUTPUTS UNBALANCED analog audio output signals to a Preamplifier or A V Control Center FIXED AUDIO OUTPUTS BAL...

Страница 9: ...ntrol Cable from the D100 POWER CONTROL OUT Jack to the Power Control In on the Tuner 2 Connect a Control Cable from the Tuner Power Control Out Jack to the SACD CD Player Power Control In Jack 3 Connect a Control Cable from the SACD CD Play er Power Control Out Jack to the Power Amplifier Power Control In Jack Note If two Power Amplifiers are used connect the Power Control Output of the first Amp...

Страница 10: ...rol In Jack 3 Connect a Control Cable from the Tuner Power Control Out Jack to the SACD CD Player Power Control In Jack 4 Connect any additional Components in a similar manner as outlined in steps 2 and 3 Data Connection 5 Connect a Control Cable from the D100 DATA IN Jack to the Analog Preamplifier or A V Control Center DVD or VIDEO Data Port Input Sensor Connection 6 Optionally connect the exter...

Страница 11: ...e LEVEL Push button to adjust the Volume Level Up or Down at the D100 Variable Outputs Connections HOME Direct access to the Digital Input 1 5 by using the Front Panel Indicated Input Number for source selection Steps thru the Digital Inputs 1 5 for source selection Press the area of the push button to switch power On or Off to the D100 ...

Страница 12: ...impedance dynamic headphones for private listening MUTE Push button with indicator mutes the audio from the Loudspeakers INPUT Control allows the selection of digital sources 1 5 for listening INFORMATION DISPLAY indicates the Source Volume Level Sampling Frequency Bit Depth Operational Functions and Setup Mode Settings Front Panel Displays Controls Push buttons and Jack SETUP Push button with ind...

Страница 13: ...play HIGH 13 FIRMWARE V_ _ __ 13 1 In some Countries and or Localities the default setting of Auto Power Off Feature is ENABLED Setup Brightness Figure 1 LEVEL 76 Figure 2 1 C OAX1 FIRMW ARE V1 00 Figure 3 The D100 incorporates an Auto Power Off Feature which can automatically place the Digital Preampli fier into the Power Saving Standby Off Mode This occurs approximately 30 minutes after there ha...

Страница 14: ...the Loudspeakers Note The Headphone Output is optimized for imped ances ranging from 20 to 600 ohms Power On and Off The Red LED above the STANDBY ON Push but ton lights to indicate the D100 is in Standby mode To switch ON the D100 press the STANDBY ON Push button on the Front Panel or the Power On Push button on the Remote Control The D100 will go through a brief startup initialization with the F...

Страница 15: ...When the D100 Information appears down load the McIntosh Audio Windows Driver Installa tion and Operation Guide and McIntosh USB Audio Windows Driver V_ _ Follow the instructions in the How to Operate the D100 McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com USB Audio Windows Driver Installation and Operation Guide Guide and after the...

Страница 16: ...16 ...

Страница 17: ...17 Photos ...

Страница 18: ...50 60Hz at 20 watts 120 Volts 50 60Hz at 20 watts 220 Volts 50 60Hz at 20 watts 230 Volts 50 60Hz at 20 watts 240 Volts 50 60Hz at 20 watts Standby Power less than 0 25 watts Note Refer to the rear panel of the D100 for the correct voltage Overall Dimensions Width is 17 1 2 inches 44 45cm Height is 3 7 8 inches 9 8cm including feet Depth is 16 inches 40 64cm including the Front Panel Knobs and Cab...

Страница 19: ...the original shipping carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Customer Service Depart ment of McIntosh Laboratory Refer to page 4 Please see the Part List for the correct part numbers Quantity Part Number Description 1 033838 Shipping carton only 4 033837 End cap 1 033836 Inside ...

Страница 20: ...ucts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcintoshlabs com McIntosh Part No 04138700 ...

Отзывы: