Problem

Possible Cause

Solution

Dehumidifi er does not run

Unit is not plugged in

Unit is not connected to a 
properly rated AC power source

Plug in the unit

Check that the unit is prop-
erly connected to an AC power 
source. Also check that the 
circuit protector for the recep-
tacle is on. 

If properly connected, turn the 
humidistat knob all the way to 
the “on” position. If the unit 
still doesn’t run, contact Arrow 
Dryers’ technical support. 

The unit doesn’t perform opti-
mally

Airfl ow is restricted

Too much airfl ow from the 
outside

Evaporator coils are dirty

Low humidity and temperature

Check that there is adequate 
airfl ow toward and around the 
unit. Consider using an external 
fan to move the air around and 
toward the unit. Check that 
nothing is blocking the unit. 

Close all outside doors, hatch-
es, portholes, etc. 

Dirty coils interfere with the 
dehumidifi er’s ability to re-
move moisture from the ambi-
ent air. Have the evaporator 
coils properly cleaned.

Check the humidity fi rst. At a 
low humidity level and temper-
ature below 65F, the amount of 
moisture that can be collected 
is greatly reduced. Set the 
humidistat to 60% RH. If the 
temperature and humidity are 
high, call Arrow Dryers’ techni-
cal support. 

There is a rattling sound and 
the compressor shakes when 
the unit is moved. 

The compressor is built and 
mounted in the chassis in such 
a way as to absorb movement. 
It is perfectly normal to hear 
the compressor rattle and feel 
it shake. 

Caution: Do not rapidly cycle the unit on and off. Allow a few minutes before restarting to pro-
tect the overload circuit. 

Troubleshooting

Pg. 5

Содержание DH-10

Страница 1: ...old and Mildew Growth Helps Eliminate Musty Odors Reduces Condensation Features Lightweight Steel Cabinet Lowest Power Consumption Continuous Drain Convenient Carrying Handles Automatic Humidistat Compact and Portable Design UL Approved Specifications Weight 38 Lbs Dimensions LxWxH 15 5 x 12 x 12 5 Energy Use 150 Watts at 115 VAC Starting Current 194 4 Watts Humidistat 20 80 Relative Humidity Ambi...

Страница 2: ...a wall or ceiling mount ensure that the unit is mounted securely and remains level 6 Do not store or use flammable chemicals gases or liquids such as gasoline or diesel fuel in the vicinity of this unit or any other electrical appliances 7 If used on a boat do not operate the dehumidifier or other electrical appli ance in the bilge or engine room where gasoline diesel fuel or other combus tible va...

Страница 3: ...e be sure to not cause any kinks or other sharp bends in the hose Do NOT drink the water that collects in the drain pan Operation Be sure to plug the unit into a 3 prong grounded receptacle that has a properly rated and protected AC power source such as shore power or an inverter 1 The dehumidifier runs on normal AC only 115 VAC household or shore power Make sure it is connected to a grounded 3 pr...

Страница 4: ...which could result in an explosion 3 Do not store or use flammable chemicals gases or liquids such as gasoline or diesel fuel in rooms with an RH below 30 since in a very dry room static electricity discharge may ignite combustible vapors which may result in an explosion Cleaning and Maintenance Use a non abrasive cleanser on the cabinet and wipe off with a clean rag to keep the cabinet looking ne...

Страница 5: ...e the air around and toward the unit Check that nothing is blocking the unit Close all outside doors hatch es portholes etc Dirty coils interfere with the dehumidifier s ability to re move moisture from the ambi ent air Have the evaporator coils properly cleaned Check the humidity first At a low humidity level and temper ature below 65F the amount of moisture that can be collected is greatly reduc...

Страница 6: ...n and other factors may need to be addressed when storing your equipment These agents may include visible light ul traviolet radiation tempurature dirt etc which may effect your environment These ranges only address relative humidity levels as recommended by the NPS Paintings 40 65 Paper 45 55 Photographs Film Negatives 30 40 Other Organics wood leather textiles etc 45 60 Metals 35 Pg 6 ...

Страница 7: ...e unit toward the problem area is DO NOT operate the dehumidifier or other electrical appliances in the bilge engine room or fuel storage rooms where gasoline deisel or other combustible vapors may accumulate If using in a home bathrooms laundry rooms and basement crawl spaces are ideal locations for the dehumidifier 4 Who is the manufacturer DH 10 Dehumidifiers are manufactured in the USA by McIn...

Страница 8: ...n to McIntire Company without prior authorization and an RGA number To contact McIntire Company for repair or warranty service 745 Clark Ave Bristol CT 06010 Toll Free 800 437 9247 Fax 860 314 4500 This warranty is good only in the continental boundary of the United States For export consult factory Pg 8 ...

Отзывы: