Air Compressor Safety Warnings

1. 

Risk of fire or explosion - do not spray 

flammable liquid in a confined area or towards a 

hot surface.  Spray area must be well-ventilated.  

Do not smoke while spraying or spray where 

spark or flame is present.  Arcing parts - keep 

compressor at least 20 feet away from explosive 

vapors, such as when spraying with a spray gun.

2. 

Risk of bursting - do not adjust regulator higher 

than marked maximum pressure of attachment.

3. 

Risk of injury - do not direct air 

stream at people or animals.

4. 

Do not use to supply breathing air.

5. 

Do not leave compressor unattended 

for an extended period while plugged in.  

Unplug compressor after working.

6. 

Keep compressor well-ventilated.  

Do not cover compressor during use.

7.  Drain Tank daily and after use.  Internal rust causes 

tank failure and explosion.

8.  Do not remove the valve cover or 

adjust internal components.

9.  Compressor head gets hot during operation.  

Do not touch it or allow children nearby 

during or immediately following operation.

10. Do not use the air hose to move the compressor.

11.  Release the pressure in the 

storage tank before moving.

12. The use of accessories or attachments not 

recommended by the manufacturer may 

result in a risk of injury to persons.

13. All air line components, including hoses, pipe, 

connectors, filters, etc., must be rated for a minimum 

working pressure of 150 PSI, or 150% of the 

maximum system pressure, whichever is greater.

14. USE OF AN EXTENSION CORD IS NOT 

RECOMMENDED.  If you choose to use an 

extension cord, use the following guidelines:

TABLE A:  RECOMMENDED MINIMUM WIRE 

GAUGE FOR EXTENSION CORDS 

(120 VOLT)

NAMEPLATE 

AMPERES

(at full load)

EXTENSION CORD 

LENGTH

25

50

100

150

0 – 6

18

16

16

14

6.1 – 10

18

16

Do not use.

10.1 – 12

16

16

Do not use.

12.1 – 16

14

12

Do not use.

a.  Make sure your extension cord 

is in good condition.

b.  Be sure to use an extension cord which 

is heavy enough to carry the current your 

product will draw.  An undersized cord will 

cause a drop in line voltage resulting in loss 

of power and overheating.  Table A shows the 

correct size to use depending on cord length 

and nameplate ampere rating.  If in doubt, 

use the next heavier gauge.  The smaller 

the gauge number, the heavier the cord.

15. Industrial applications must follow OSHA guidelines.

16. Maintain labels and nameplates on the 

compressor.  These carry important safety 

information.  If unreadable or missing, contact 

Harbor Freight Tools for a replacement.

17. This product is not a toy.   

Keep it out of reach of children.

18. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 

close proximity to heart pacemaker could cause 

pacemaker interference or pacemaker failure.

 SAVE THESE INSTRUCTIONS.

Содержание 57572

Страница 1: ...reference 21h When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2020 by Harbor Freight Tool...

Страница 2: ...ty alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if...

Страница 3: ...Do not use this compressor while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a compressor may result in serious personal injury b Use pe...

Страница 4: ...may result in a risk of injury to persons 13 All air line components including hoses pipe connectors filters etc must be rated for a minimum working pressure of 150 PSI or 150 of the maximum system p...

Страница 5: ...nt grounding conductor can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If...

Страница 6: ...section at the beginning of this manual including all text under subheadings therein before set up or use of this product TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF...

Страница 7: ...ower Cord 5 Turn Power Switch ON 6 Let unit run for 15 minutes Air will expel freely through the Drain Valve 7 Turn Power Switch OFF 8 Unplug Power Cord and close Drain Valve Air Connection Setup 1 Co...

Страница 8: ...resent at connections tighten connections Do not use the Air Compressor unless all connections are air tight the extra air leaking out will cause the compressor to operate too often increasing wear on...

Страница 9: ...any issues before further use to avoid damage to the compressor Maintenance and Servicing Procedures not specifically explained in this manual must be performed only by a qualified technician TO PREVE...

Страница 10: ...or air bubbles To clean the compressor surface wipe with a damp cloth using a mild detergent or mild solvent Monthly Inspect Safety Valve Draining Moisture from the Tank The Moisture Drain is located...

Страница 11: ...sor not large enough for job 4 Loose fittings 5 Hose or hose connections too narrow 6 High altitude reducing air output 1 Check inlet and outlet filters Clean and or replace as needed 2 Have technicia...

Страница 12: ...ALLATION OF REPLACEMENT PARTS THERETO 57572 Parts List Part Description Qty 1 Drain Valve 1 2 Feet 4 3 Tank 1 4 Power Cord 1 5 Tension Disc 1 6 Screw ST4 2 15 F 6 7 Hose 1 8 Clamp 4 9 NPT 1 8 Two Way...

Страница 13: ...Page 13 For technical questions please call 1 888 866 5797 Items 57572 57567 SAFETY OPERATION MAINTENANCE INSTALLATION 57572 Assembly Diagram...

Страница 14: ...Cover 1 21 Piston 1 22 O Ring 1 23 Muffler Bottom Cover 1 24 Connecting Rod 1 25 Ball Bearing 608 2rs 1 26 Hex Screw M6 20 3 27 Crankshaft 1 28 Flat Washer 6 2 29 Circlip 2 Part Description Qty 30 Bra...

Страница 15: ...Page 15 For technical questions please call 1 888 866 5797 Items 57572 57567 SAFETY OPERATION MAINTENANCE INSTALLATION 57567 Assembly Diagram...

Страница 16: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Отзывы: