1 - 4
Operation
Insertion Depth
Measure and mark the insertion depth on the pipe before
installing the test cap to ensure proper set up.
The gauge line (Caption “A” of diagram) on the outside of the
test cap, is used for correctly marking the pipe to its proper
insertion depth
To correctly mark the insertion depth, place the pipe alongside the
test cap, marking the length from the gauge line (A) to the end of
the test cap on the pipe.
Insertion depths for all sizes of test caps are shown in the table.
IMPORTANT:
The proper gripping action of the grip plates
requires that the pipe move out of the test cap as the pressure is
applied. This movement can be as much as 3/8".
TX02257-3-8-04
CD00180-10-26-95
CD00637-1-2-01
1/2" IPS
3-1/8"
TP-302
1/2" CTS
3-1/8"
TP-301
3/4" IPS
3-1/8"
TP-304
3/4" CTS
3-1/8"
TP-303
1" IPS
3-3/8"
TP-306
1" CTS
3-3/8"
TP-305
1-1/4" IPS
3-5/8"
TP-308
1-1/4" CTS
3-3/8"
TP-307
1-1/2" IPS
3-5/8"
TP-309
2" IPS
4-1/8"
TP-310
Size
Insertion
Depth
Part #
Test Cap Lanyard
This device consists of a cable with rings on both ends. In the
event that the test cap is accidentally dislodged, the lanyard is
designed to minimize the travel of the test cap by wedging itself
on the pipe and the cap plumbing. The lanyard may be required
by your local regulations.
Install the adapter ring (smallest ring) of the lanyard around the
fitting (user supplied) behind the test cap. This will ensure that the
lanyard will remain secured to the test cap at all times.
Inspect the lanyard for damage or wear prior to each use.
Replace if damaged or worn.
TX02258-3-8-04
CD00399-4-1-04
PH01238-4-1-04
PH02702-5-6-04