Pipe Stand Selection Chart
Fusion Machine
How to use this chart:
The MegaMc Hydraulic Pipe Stands are intended for use with the MegaMc fusion machines. The 8-36 pipe stand
is best matched to the 824, T630, 1236 and T900 fusion machines. The 36-65 pipe stand is best matched to the
1236, T900, 1648, 2065 and 1600 fusion machines. There is some capability overlap so this chart details all
the combinations of pipe size and MegaMc fusion machines that can be used with the 8-36 and 36-65 MegaMc
Hydraulic Pipe Stands.
To determine which pipe stand to use, locate the pipe size at left of chart and fusion machine at top of chart. Where
the two intersect will fall within the operating envelope of either the 8-36 or 36-65 pipe stand or both. The chart is
based on the fusion machine and pipe stand being on level ground. Uneven ground will shift the effective operating
envelopes. For heavy wall pipe, ensure that the weight of a stick of pipe does not exceed the pipe lift capacity of
9,000 lbs. for 8-36 and 16,000 lbs. for 36-65.
To reach some small pipe sizes in a 65 fusion machine, the pipe stand must be blocked up.