PACKAGING and UNPACKING 

 

CartCleaner UV is supplied and delivered completely assembled. 

The packaging made with wooden pallet, covered and protected by heat shrink plastic wrap. 

Two ties, strapped on the long side and one on the short side to secure the machine to the pallet. 

 

To remove the machine

, proceed as follows: 

Cut the tyings, remove the protection plastic film wrap. 

Lift the machine from the pallet and place it on the ground. 

Place the machine in the work area. 

 

Dispose of the packaging according to the regulations in place. 

 

 

TRANSPORT AND INTERNAL HANDLING

 

 

Transport must be carried out by qualified personnel with suitable means. 

 

The machine, even if packed, must be transported so as to avoid any damage to its parts. 

The lifting of the machine must be carried out using forklifts suitable for the type of pallet. 

For internal handling, precautions as described above must be used. 

To  facilitate  the  positioning  of  the  machine  in  the  work  area,  with  manual  pallet  trucks,  the 

machine is provided with special gripping bars that facilitate handling. 

Once the machine is positioned, the bars must be removed. 

 

 

 

INSTALLATION 

 

CartCleaner UV does not need any particular installation operations. 

The machine is ready for use, simply connect it to a power source by connecting it directly to a 

power outlet compliant with current safety standards. 

It is the responsibility of the user to connect the machine to a compliant power supply system, 

with an effective and verified grounding system, both with certification of conformity. 

The  machine  must  be  connected  directly  to  the  power  supply  socket  without  the  use  of 

extension cables or adapters. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CartCleaner UV

Страница 1: ...CartCleaner UV 1 USE AND MAINTENANCE MANUAL CARTCLEANER UV ...

Страница 2: ...AL 10 GUARANTEE 11 ATTACHMENTS A Mechanical diagrams and spare parts list B Wiring diagram and spare parts list C Technical data and instructions for use and maintenance of the single components installed Note the photos and illustrations possibly included in these instructions provide a purely indicative view of the elements that could be installed any aesthetic or appearance differences with res...

Страница 3: ...nitise shopping carts shopping baskets luggage trolleys other equipment and objects thus also gaining a significant image of special care towards your customers SANITIZE means to make safe in terms of hygiene by eliminating or making inactive bacteria fungi and viruses Our machine and the innovation of our product allows you to obtain an excellent result avoiding the use of dangerous or toxic subs...

Страница 4: ...described in this manual complies with the essential safety and health protection requirements of the Directives Low Voltage Directive 2006 95 CE and Electromagnetic Compatibility Directive 2004 108 CE The following Harmonized Standards have been consulted to verify the Conformity referred to in the aforementioned Directives 2014 35 UE Low Voltage Directive LVD 2014 30 UE Electromagnetic Compatibi...

Страница 5: ... Monophase Maximum absorbed power 250 Watt Weight 120 kg ca Degree of electrical protection IP 40 Power cable civilian type Schuko plug with cable length 3 meters Overall dimension Base mm 900 Height mm 1350 Depth mm 1450 Entrance door trolley dimensions clear opening Base mm 770 Height mm 1250 Control circuit power supply 12 24 Volt DC ...

Страница 6: ...ting the machine to the mains it will be necessary to check that The main power supply voltage corresponds to that indicated on the identification plate located on the rear of the machine The network power system is equipped with effective grounding and that the power outlet has a minimum capacity of 10A Check that the main machine switch is turned off Check that the power supply cable of the mach...

Страница 7: ...e to its parts The lifting of the machine must be carried out using forklifts suitable for the type of pallet For internal handling precautions as described above must be used To facilitate the positioning of the machine in the work area with manual pallet trucks the machine is provided with special gripping bars that facilitate handling Once the machine is positioned the bars must be removed INST...

Страница 8: ...le Inside the machine in a special hidden compartment the following parts are housed 24 Volt DC control circuit power supply Lamp switch power remote control N 5 reactors to power the UV lamps 40 watts 230 Volt Wiring carried out with conductors and cables placed in PVC containment channels Inside the sanitizing compartment on the top ceiling the following components are installed N 5 Actinic lamp...

Страница 9: ... fire or broken lamps immediately press the Emergency button on the front of the machine disconnect the machine from the power supply and call the staff and or contact the service center MAINTENANCE CartCleaner UV needs only simple maintenance work Suggested interventions Periodically check the operation of the lamps every 3 months Periodically check the operation of the differential switch by pre...

Страница 10: ...letely protected and isolated Possible failures in case of contact or electric discharge towards the metal structure The occurrence of this event is very low as the whole structure is connected to the equipotential earth conductor Moreover the system is equipped with a differential switch with an intervention threshold of 30 mA which upon exceeding the same interrupts power to the apparatus DANGER...

Страница 11: ...e delivery date of the first product The defect must be exclusively verified by the technical staff appointed by the manufacturer Shipping costs of the product are at customer s charge The guarantee is not liable for damages During transport for repair needs as the machine travels under the responsibility of the customer When the faults arise from improper negligent or incorrect use of the machine...

Отзывы: