Cabling the T-200 NTBA Appliance
The T-200 NTBA Appliance has four collection ports and one management port.
The collection ports connect to the network infrastructure that generates the NetFlow data from routers and
McAfee
®
Network Security Sensor (Sensor)s.
The four collection ports can be used to distribute the NetFlow data from different routers and Sensors.
The management port connects to a network device that in turn connects to the Manager. The NTBA
Appliance is managed through the Manager.
Ports for cabling in the back panel
Figure 6 T-200 back panel ports
Item
Description
1
Console port
2
Management port
3
Collection ports (2-copper)
4
Collection ports (2-copper)
9
Connect the console ports
a
Plug a console cable (RJ45 to DB9 serial) to the console port at the back panel of the NTBA Appliance.
b
Connect the other end of the cable directly to the serial port of the PC or Terminal Server you will be
using to configure the NTBA Appliance (for example, a PC running correctly configured Windows
HyperTerminal software.)
6