MC2 Audio HS Series Скачать руководство пользователя страница 16

Page 16 

 

HS Series – HS1400/800 Operating Instructions 

 

 

 

 

 

 

Performance Of Your Amplifier:  Specifications 
 

Main Specifications  
 

Parameter (Units) 

HS1400 

HS800 

Output Power per channel [Crest Factor = 4.8] (Watts) 

 

 

8 Ohms 

775 

475 

4 Ohms 

1500 

950 

Output Power per channel bridged [Crest Factor = 4.8] (Watts)

 

 

 

8 Ohms 

3000 

1900 

THD+N, 4 Ohms (%) 

 

 

@1kHz, 1dB below max output power  

<

 

0.008 

0.007 

@20Hz - 20kHz, 1dB below max output power 

<

 

0.03 

0.03 

Gain Options (dB) 

32 / 36 

32 / 36 

Sensitivity Options for max power (dBu) 

8.0 / 4.0 

5.5 / 1.5 

Sensitivity Options for max power (Volts) 

2.0 / 1.2 

1.4 / 0.9 

Frequency Response, +0/0.5dB (Hz) 

20 — 20000 

20 — 20000 

Power Consumption, Nominal @ 240V, 4 Ohms (A) 

3.2 

2.1 

Power Consumption, Nominal @ 120V, 4 Ohms (A) 

6.4 

4.2 

Dimensions H x W x D (mm) 

 

 

Amplifier 

88 x 482 x 428 

88 x 482 x 428 

Boxed 

230 x 580 x 560 

230 x 580 x 560 

Boxed Shipping — all except UK 

250 x 610 x 600 

250 x 610 x 600 

Weight (kgs) 

 

 

Amplifier 

23.25 

20.5 

Boxed — shipping 

25 

22.25 

 
Additional Specifications 
 

Parameter (Units) 

HS1400 

HS800 

Input Impedance — Active Balanced (Ohms) 

20k 

20k 

Input CMRR (dB) 

 

 > 

60 

60 

SNR (dB) 

106 

106 

Damping Factor, 1kHz, 8 ohms 

400 

400 

Signal Limiters Present 

Yes 

Yes 

Protection Present — Short Circuit / DC Output / Temperature 

Yes 

Yes 

Mains In-rush Control Present 

Yes 

Yes 

Output Power per channel, 8 Ohms (Watts) 

 

 

Sine Wave @ 1kHz 

650 

450 

Continuous music [Crest Factor of 2.8 or 9dB] 

725 

475 

Continuous music [Crest Factor of 4.8 or 14dB] 

775 

475 

Continuous music [Crest Factor of 7.8 or 18dB] 

775 

500 

Output Power per channel, 4 Ohms (Watts) 

 

 

Sine Wave @ 1kHz 

1250 

800 

Continuous music [Crest Factor of 2.8 or 9dB] 

1450 

900 

Continuous music [Crest Factor of 4.8 or 14dB] 

1500 

950 

Continuous music [Crest Factor of 7.8 or 18dB] 

1500 

1000 

 
Due to continuing product improvement the above specifications are subject to change. 
*Power output is automatically limited to this value on the HS1400 model. 

Содержание HS Series

Страница 1: ...eference Power Amplifiers MC HS1400 HS800 Operating Instructions MC www mc2 audio co uk Tel 44 0 1404 44633 Fax 44 0 1404 44660 MC AUDIO Units 6 8 Kingsgate Heathpark Industrial Estate Honiton Devon England EX14 1YG 2 ...

Страница 2: ...Page 2 HS Series HS1400 800 Operating Instructions ...

Страница 3: ...nsiderations 9 Connecting To Your Amplifier Inputs and Link Outs 10 Connecting To Your Amplifier Speaker Outputs 11 Connecting To Your Amplifier Bridged Mono Operation 11 Operating Your Amplifier Front Panel Controls and Indicators 12 Operating Your Amplifier Notes and Switching On 13 Operating Your Amplifier Rear Panel Sockets and Switches 14 Looking After Your Amplifier Maintenance 15 Looking Af...

Страница 4: ...0 T4 250 Ti500 Ti1000 Ti1500 Ti2000 Ti3500 Ti4 250 E15 E25 E45 E90 E100 E475 S800 S1400 HS800 HS1400 and all OEM variants of these models are manufactured in accordance with EMC Directive 2004 108 EC in compliance with the following norm s or document s Technical Regulations EN55103 1 1996 EN55103 2 1996 and in accordance with the Low Voltage Directive 2006 95 EC in compliance with the following n...

Страница 5: ...focus the HS Series amplifiers deliver the sound quality and reliability expected from MC2 These amplifiers utilise the best complimentary AB bipolar output stages combined with the unique MC2 current driven floating drive stage along with analogue level controls for minimal signal degradation Sophisticated side chain limiters prevent distortion and speaker damage but are out of circuit until the ...

Страница 6: ...ashing and ensure that no objects filled with liquids such as vases are placed on the equipment To completely disconnect this equipment from the AC mains disconnect the power cord from the mains circuit breaker Where the amplifier is mounted in a rack and permanently connected to the mains then the rack should be installed with a readily accessible connector or an ALL POLE circuit breaker with 3mm...

Страница 7: ...li des liquides comme les vases n est placé sur l équipement Pour complètement débrancher cet équipement de la conduite principale de courant alternatif débranchez la corde de pouvoir du disjoncteur de conduite principale Où l amplificateur est monté dans un égouttoir et en permanence raccordé à la conduite principale alors l égouttoir devrait être installé avec un connecteur sans hésiter accessib...

Страница 8: ...sible connector or an ALL POLE circuit breaker with 3mm breaking distances This unit is fitted with a 3 wire power cord For safety reasons THE EARTH LEAD SHOULD NOT BE DISCONNECTED IN ANY CIRCUMSTANCE If ground loops are encountered consult the section on connecting your amplifier on page 10 The wiring colours are 230V AREAS EARTH GREEN AND YELLOW 120V AREAS EARTH GREEN NEUTRAL BLUE NEUTRAL WHITE ...

Страница 9: ...ing the amplifier in a rack or enclosure Be aware that THE FRONT PANEL IS NOT CAPABLE OF SUPPORTING THE UNIT ON ITS OWN Make sure that the rear of the unit is adequately supported The brackets which are supplied fit standard 19 inch 483mm rack mounting systems ENSURE THERE IS ADEQUATE VENTILATION The cooling fans suck cool air in through the front and blow hot air out at the rear of the unit throu...

Страница 10: ... the unbalanced equipment or left disconnected at the unbalanced end PIN2 Hot signal PIN3 Cold ground 0V NOTE This amplifier is wired to the latest industry recommendations PIN1 is connected directly to the chassis mains earth If ground loops mains hum are encountered remove the screen connection from the other end of the cable and leave it open circuit If problems persist consult your dealer supp...

Страница 11: ...ds Do not connect the inputs outputs to any other voltage source such as a battery mains source or power supply regardless of whether the amplifier is turned on or off Do not run the output of any amplifier channel back into another channel s input and do not parallel or series connect an amplifier output with any other amplifier output Connecting To Your Amplifier Bridged Mono Operation Although ...

Страница 12: ...otection circuit will disengage the outputs and the Protect LED will illuminate The amplifier will continue to be monitored and depending on the type of fault will either reset after the fault has cleared or require manual resetting by switching off at the mains switch and then on again after a few seconds Temperature related faults will reset if the unit has cooled sufficiently Output short circu...

Страница 13: ...e the free flow of air around the unit If the unit is used in an extremely dusty or smoky environment it should be cleaned of any collected debris at regular intervals Please also see the notes regarding maintenance on page 15 It is important that the power output of your amplifier is matched to the power handling capacity of your loudspeaker If not damage to the loudspeaker could occur Switching ...

Страница 14: ... positive terminal in bridged mode 6 Channel B output binding posts Connect speaker with either bare wires or 4mm banana plugs Note that in bridged mode the positive terminal only is used for the hot side of the load No connection is made to the negative terminal in bridged mode 7 Mains inlet Connect a suitably rated 3 core IEC mains cable CAUTION This unit must be earthed To reduce the risk of fi...

Страница 15: ...olvents as they will damage the paint finish and could remove printing If you have any doubts about carrying out maintenance please refer to a service engineer or contact your local dealer Looking After Your Amplifier Warranty Your amplifier is guaranteed for a period of five 5 years from the date of manufacture Please note that this does not apply to OEM versions of the amplifier please consult y...

Страница 16: ...all except UK 250 x 610 x 600 250 x 610 x 600 Weight kgs Amplifier 23 25 20 5 Boxed shipping 25 22 25 Additional Specifications Parameter Units HS1400 HS800 Input Impedance Active Balanced Ohms 20k 20k Input CMRR dB 60 60 SNR dB 106 106 Damping Factor 1kHz 8 ohms 400 400 Signal Limiters Present Yes Yes Protection Present Short Circuit DC Output Temperature Yes Yes Mains In rush Control Present Yes...

Страница 17: ... 223 343 120 4 1 2 3 1 6 4 14 6 144 200 296 543 Power Consumption and Thermal Emissions HS800 Mains V Load R Current Draw A Thermal Emissions W No Sig l Light Average Heavy No Sig l Light Average Heavy 240 8 0 5 0 8 1 3 2 7 120 139 168 251 240 4 0 5 1 1 2 1 4 7 120 157 216 368 120 8 1 0 1 6 2 6 5 4 120 139 168 251 120 4 1 0 2 2 4 2 9 3 120 157 216 368 No Sig l Quiescent Light Crest Factor of 7 8 1...

Отзывы: