MC2 Audio E45 Скачать руководство пользователя страница 13

 

13

AIR FILTER 
 
The  filter  behind  the  air  intake  apertures  on  the  front  of  E  SERIES  amplifiers  should  be  cleaned  or 
replaced  periodically,  e.g.  3-6  months.  (Filters  in  amplifiers  located  in  more  'dirty'  atmospheres  may 
require more frequent maintenance). Access is via the blue front panel retained by 2.5mm Hex screws. 
The filter should be 'dry' cleaned, using a vacuum cleaner preferably. Running the unit without a filter is 
not recommended unless it is within a 'clean room'. Replacement filter material is available. 
 
No other regular maintenance is required. 
 

If  you  have  any  doubt  about  carrying  out  this  procedure,  refer  to  a  service  engineer  or 
contact your dealer.

 

 

IF YOUR AMPLIFIER DEVELOPS A FAULT, PLEASE REFER TO YOUR SUPPLIER FOR SERVICE 
AND  TECHNICAL  SUPPORT.  DO  NOT  ATTEMPT  TO  REPAIR  THE  FAULT  YOURSELF  AS  THIS 
WILL INVALIDATE THE WARRANTY. 

 

TECHNICAL SPECIFICATION 

 

Main Specifications - E series Amplifiers

Parameter  (Units)

E90

E45

E25

E15

E100

E475

Output Power (per channel) (Watts)

8 ohms

2500

1250

700

450

1400

775

4 ohms

4800

2500

1350

850

2800

900

2 ohms

8200

4200

2400

1550

3700

NA

Output Power (bridged) ( Watts)

8 ohms

9600

5000

2700

1700

5300

1800

4 ohms

16400

8400

4800

3100

7400

NA

THD+N:(%)(4 ohms)

@1kHz (@1dB below max output power) <

0.15

0.015

0.008

0.008

0.08

0.008

@20Hz to 20kHz (@3dB below max output power) <

0.5

0.05

0.03

0.03

0.15

0.03

Gain Options (dB) 

32/36/39

26/32/36

26/32/33

26/31/32

26/32/36

26/31/32

Sensitivity Options 

(for maximum power)

 (dBu)

13/9/6

15.7/9.7/5.7

13/7/6

11/6/5

16/10/6

11/6/5

Sensitivity Options 

(for maximum power)

 (Volts)

3.5/2.2/1.5

4.7/2.4/1.5

3.5/1.7/1.5

2.7/1.5/1.4

4.9/2.5/1.5

2.7/1.5/1.4

Frequency Response - 

20Hz to 20kHz

 (dB)

±1.0

+0 / -0.3

+0 / -0.3

+0 / -0.3

±0.5

+0 / -0.3

Power Consumption: 

Nominal @ 240v (4 ohms)

(Amps)

5.6

4.5

3

2.1

7

2.7

Power Consumption: 

Nominal @ 120v (4 ohms)

(Amps)

11.2

9

6

4.2

14

5.4

Dimensions: (mm)

Amplifier: H x W x D

                      88 x 482 x 428

Boxed (shipping UK): H x W x D

                     230 x 580 x 560

Boxed (shipping - all except UK): H x W x D

                     250 x 610 x 600

Weight: (Kgs)

Amplifier:

11.78

11.42

10.16

9.8

12

10.62

Boxed:(shipping)

13.78

13.42

11.92

11.66

14

12.62

Additional Specifications

Input Impedance - Active balanced (k ohms)

20

20

20

20

20

20

Input CMRR (dB)

>60

>60

>60

>60

>60

>60

Hum & Noise 

(dB below max output)

-105

-106

-105

-105

-105

-105

Damping Factor: 

@1kHz into 8 ohms

>400

>400

>400

>400

>400

>400

Signal Limiters - 

(set to prevent excessive clipping)

Yes

Yes

Yes

Yes

Yes

Yes

Protection: Short circuit / DC output / Temperature

Yes

Yes

Yes

Yes

Yes

Yes

Mains in-rush control.

Yes

Yes

Yes

Yes

Yes

Yes

Output Power (watts) into 8 ohms

Sine wave @ 1kHz

2400

1100

650

400

1150

725

Continuous music with Crest Factor of 2.8 (9dB)

2400

1200

675

425

1300

750

Continuous music with Crest Factor of 4.8 (14dB)

2500

1250

700

450

1400

775

Continuous music with Crest Factor of 7.8 (18dB)

2600

1350

725

475

1480

825

Output Power (watts) into 4 ohms

Sine wave @ 1kHz

4500

2050

1200

775

2250

750

Continuous music with Crest Factor of 2.8 (9dB)

4400

2400

1250

825

2600

825

Continuous music with Crest Factor of 4.8 (14dB)

4800

2500

1350

850

2800

900

Continuous music with Crest Factor of 7.8 (18dB)

5000

2700

1350

875

2900

900

Output Power (watts) into 2 ohms

Sine wave @ 1kHz

7200

3300

2200

1350

3200

NA

Continuous music with Crest Factor of 2.8 (9dB)

6800

4100

2300

1500

3600

NA

Continuous music with Crest Factor of 4.8 (14dB)

8200

4200

2400

1550

3700

NA

Continuous music with Crest Factor of 7.8 (18dB)

8900

4300

2600

1600

3700

NA

 

Содержание E45

Страница 1: ...5 E45 OWNER S MANUAL BG version BG version BG version BG version MC 2 AUDIO Ltd Units 6 8 Kingsgate Heathpark Industrial Estate HONITON Devon EX14 1YG England Tel 0 1404 44633 Fax 0 1404 44660 www mc2 audio co uk ...

Страница 2: ...cal 8 GENERAL INFORMATION 9 CONNECTIONS Inputs 10 Outputs 10 Bridged Operation 11 OPERATION Switching on 11 Level controls 11 Bar signal indicators 11 3dB indicator 11 Limiters 11 PRC indicators 11 Temperature control 12 Fault indicator 12 Bridged LED 12 MAINTENANCE 12 TECHNICAL SPECIFICATION 13 APPENDIX Table of PRC settings 14 ...

Страница 3: ...3 ...

Страница 4: ...our local power supply requirements but before connecting the unit to the supply ensure that the voltage printed on the rear panel is correct Make sure power outlets conform to the power requirements listed on the back of the unit Damage caused by connecting to improper AC voltage is not covered by the warranty SAFETY WARNING Where a MAINS plug or appliance coupler is used as the disconnect device...

Страница 5: ... particular attention to cords and plugs and the point where they exit from the appliance ALWAYS OPERATE THE UNIT WITH THE AC GROUND WIRE CONNECTED TO THE ELECTRICAL SYSTEM GROUND Precautions should be taken so that the means of grounding of a piece of equipment is not defeated DO NOT REMOVE THE LID Removing the lid will expose you to potentially dangerous voltages There are no user serviceable pa...

Страница 6: ...ced on the equipment 16 To completely disconnect this equipment from the AC mains disconnect the power cord from the mains circuit breaker 17 Where the amplifier is mounted in a rack and permanently connected to the mains then the rack should be installed with a readily accessible connector or an ALL POLE circuit breaker with 3mm breaking distances 18 This unit is fitted with a 3 wire power cord F...

Страница 7: ...t débrancher cet équipement de la conduite principale de courant alternatif débranchez la corde de pouvoir du disjoncteur de conduite principale 17 Où l amplificateur est monté dans un égouttoir et en permanence raccordé à la conduite principale alors l égouttoir devrait être installé avec un connecteur sans hésiter accessible ou TOUT le disjoncteur de PÔLE avec 3 millimètres cassant des distances...

Страница 8: ...t away from other equipment which is sensitive to magnetic fields Also this amplifier may suffer a substantial reduction in performance if it is subjected to or mounted close to equipment which radiates high RF fields When mounting the amplifier in a rack or enclosure ensure that 1 The rear of the unit is adequately supported The brackets which are supplied fit standard 19 inch 483mm rack mounting...

Страница 9: ... rear panel 2 per channel Each channel has an LED indicator GREEN active when either PRC switch is selected A full table of PRC settings and the resulting outputs are given in the Appendix The possible settings are 2dB 4dB 6dB This relates to the maximum output of the amplifier See the chart in the Appendix section at the end of this manual In bridged mode the Channel A PRC circuit operates over b...

Страница 10: ...sis mains earth If ground loops mains hum are encountered remove the screen connection from the other end of the cable and leave it open circuit If problems persist consult your dealer supplier DO NOT TAMPER WITH OR ALTER ANY GROUND EARTH CONNECTIONS INSIDE THE AMPLIFIER For BRIDGED OPERATION input should be made to channel A only and the rear panel switch set for bridged mode OUTPUTS Channel A an...

Страница 11: ...ise Assuming no faults are detected after a few seconds only the POWER LED and SIGNAL indicators if signal is applied will illuminate PANEL CONTROLS AND INDICATORS Level controls These are analogue controls allowing precise level settings Note that in BRIDGED mode only channel A control is active Signal Indicators 3 Green LEDs These are active from a minimum output level of approximately 10 Watts ...

Страница 12: ...lts will reset once the unit has cooled sufficiently Output short circuits will require manual reset after clearing the fault Bridged LED green This indicates the position of the switch on the rear panel and is illuminated when bridged mode is selected with the switch pressed in Maintenance CAUTION These servicing instructions are for use by qualified personnel only Ensure that Electrical power to...

Страница 13: ...4 4 9 2 5 1 5 2 7 1 5 1 4 Frequency Response 20Hz to 20kHz dB 1 0 0 0 3 0 0 3 0 0 3 0 5 0 0 3 Power Consumption Nominal 240v 4 ohms Amps 5 6 4 5 3 2 1 7 2 7 Power Consumption Nominal 120v 4 ohms Amps 11 2 9 6 4 2 14 5 4 Dimensions mm Amplifier H x W x D 88 x 482 x 428 Boxed shipping UK H x W x D 230 x 580 x 560 Boxed shipping all except UK H x W x D 250 x 610 x 600 Weight Kgs Amplifier 11 78 11 42...

Страница 14: ...ication if it is installed and operated as described in this manual APPENDIX Table of PRC settings and average relative output E45 E45 E45 E45 Output Per Channel Watts Bridged Mode Watts Max Power into 4ohm 2250 6400 2dBu PRC Setting 1400 4000 4dBu PRC Setting 900 2500 6dBu PRC Setting 560 1600 Max Power into 8ohm 1200 4400 2dBu PRC Setting 800 2800 4dBu PRC Setting 525 1800 6dBu PRC Setting 350 1...

Отзывы: