![MC2 Audio E4-75 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/mc2-audio/e4-75/e4-75_operating-instructions-manual_1753097019.webp)
E Series – E475 Operating Instructions
Page 19
Performance Of Your Amplifier: Specifications
Power Consumption and Thermal Emissions — E90
Mains
(V)
Load
(R)
Current Draw
(A)
Thermal Emissions
(W)
No Sig’l
Light
Average
Heavy
No Sig’l
Light
Average
Heavy
240
8
1.2
1.7
2.5
4.7
288
319
367
494
240
4
1.2
1.8
2.7
5.0
288
321
379
515
240
2
-
-
-
-
-
-
-
-
120
8
2.4
3.4
5.0
9.4
288
319
367
494
120
4
2.4
3.6
5.4
10.1
288
321
379
515
120
2
-
-
-
-
-
-
-
-
No Sig’l = Quiescent, Light = Crest Factor of 7.8(18dB),
Average = Crest Factor of 4.8(14dB), Heavy = Crest Factor of 2.8(9dB)
For details of measurement methods please refer to the Technical Support area of our website.
PRC Settings and Maximum Output
Power Reduction Control Setting
Per Channel
Bridged
Output Power per channel [Crest Factor = 4.8] (Watts)
8 Ohms
775
1800
-3dB PRC
405
940
Output Power per channel [Crest Factor = 4.8] (Watts)
4 Ohms
900
N/A
-3dB PRC
470
N/A