Preface 

About this User's Guide 

What you will learn from this user's guide 

This user's guide describes the Measurement Computing USB-234-OEM data acquisition device and lists 

device specifications. 

Conventions in this user's guide 

For more information 

Text presented in a box signifies additional information related to the subject matter.  

Caution!

 

Shaded caution statements present information to help you avoid injuring yourself and others, 

damaging your hardware, or losing your data.  

bold

 text 

Bold 

text is used for the names of objects on a screen, such as buttons, text boxes, and check boxes. 

italic

 text 

Italic

 text is used for the names of manuals and help topic titles, and to emphasize a word or phrase. 

Where to find more information 

Additional information about USB-234-OEM hardware is available on our website a

www.mccdaq.com

. You 

can also contact Measurement Computing Corporation with specific questions.  

 

Knowledgebase: 

kb.mccdaq.com

 

 

Tech support form: 

www.mccdaq.com/support/support_form.aspx

 

 

Email: 

[email protected]

 

 

Phone: 508-946-5100 and follow the instructions for reaching Tech Support 

For international customers, contact your local distributor. Refer to the International Distributors section on our 

website at 

www.mccdaq.com/International

. 

 

Содержание USB-234-OEM

Страница 1: ...USB 234 OEM Analog and Digital I O User s Guide January 2019 Rev 4 Measurement Computing Corporation...

Страница 2: ...d in any form by any means electronic mechanical by photocopying recording or otherwise without the prior written permission of Measurement Computing Corporation Notice Measurement Computing Corporati...

Страница 3: ...tails 9 Analog input acquisition modes 9 Software paced mode 9 Hardware paced mode 9 Board components 10 USB connector 10 Header connector J2 10 Signal connections 11 Analog input 11 Analog output 13...

Страница 4: ...USB 234 OEM User s Guide 4 Power output 23 USB specifications 23 Environmental 24 Mechanical 24 Header connectors 24 Differential mode pinout 24 Single ended mode pinout 25...

Страница 5: ...f objects on a screen such as buttons text boxes and check boxes italic text Italic text is used for the names of manuals and help topic titles and to emphasize a word or phrase Where to find more inf...

Страница 6: ...ed device that is compatible with USB 3 0 ports The device is also compatible with USB 1 1 ports but use with this older hardware is not recommended due to longer initialization times that can occur w...

Страница 7: ...USB 234 OEM User s Guide Introducing the USB 234 OEM 7 Functional block diagram Device functions are illustrated in the block diagram shown here Figure 1 USB 234 OEM functional block diagram...

Страница 8: ...on a Windows platform Connect the USB 234 OEM to a to an available USB port on the computer running Windows Connect the other end of the cable to the micro USB connector on the device No external powe...

Страница 9: ...mode You can acquire data from up to eight channels in hardware paced mode The analog data is continuously acquired and converted to digital values until you stop the scan Data is transferred in bloc...

Страница 10: ...Do not connect to connector pins labeled NC J2 differential pinout Pin Signal name Pin description Pin Signal name Pin description 1 AOUT0 Analog output 0 2 AOUT1 Analog output 1 3 AGND Analog ground...

Страница 11: ...O6 DIO bit 6 27 DIO7 DIO bit 7 28 NC No connection 29 TRIG Digital trigger input 30 NC No connection 31 NC No connection 32 GND Digital ground 33 CTR Counter input 34 VO User voltage output Signal con...

Страница 12: ...ion on page 11 Differential configuration When configured for differential input mode the input signal is measured with respect to the low input and delivered through three wires Connect the wire carr...

Страница 13: ...e no longer than 0 5 m 20 in Avoid scanning faster than necessary Design your system to scan at slower speeds to give the DAQ device more time to settle to a more accurate level when switching between...

Страница 14: ...a separate command to the hardware to initiate each DAQ conversion Software paced generations are also referred to as immediate or static operations They are typically used for writing a single value...

Страница 15: ...ng is not liable for any damage resulting from such signal connections Power on states At system startup and reset the USB 234 OEM sets all DIO lines to high impedance inputs The device does not drive...

Страница 16: ...USB 234 OEM to the USB host through the 34 pin connector do not connect to the USB connector Status LED driver LED The LED signal indicates the device status as shown in the following table LED State...

Страница 17: ...ce Regulated 5 V supply 5 V Protection Circuit for overvoltage over current and short circuit protection The 5 V source is limited at 200 mA typically In case of hard short circuit to ground this limi...

Страница 18: ...st connected to the USB connector or when the device is in suspend mode Ground The analog ground AGND connectors provide a common ground for all analog channels The digital ground GND connectors provi...

Страница 19: ...USB 234 OEM User s Guide Functional Details 19 Mechanical drawings Figure 12 Circuit board dimensions...

Страница 20: ...100 kS s Number of channels 8 single ended or 4 differential software selectable Input voltage range 10 V Working voltage 10 V Overvoltage protection Power on 30 V max Power off 20 V max Input impedan...

Страница 21: ...re full scale 32 mV INL 4 LSB DNL 16 bits no missing codes Power on state 0 V Startup glitch 7 V for 10 s Timebase The following specifications apply to hardware paced analog input and analog output s...

Страница 22: ...utput Table 6 Digital output specifications Parameter Condition Specification Output low voltage 4 mA 0 7 V max 1 mA 0 2 V max Output high voltage 4 mA 2 1 V min 1 mA 2 8 V min 3 6 V max Maximum outpu...

Страница 23: ...ent 165 mA Maximum load USB current 500 mA Note 3 Note 2 A typical bus powered hub provides 100 mA on its USB lines The USB 234 OEM does not work on a bus powered hub Note 3 The maximum power draw fro...

Страница 24: ...connector pins labeled NC Table 16 J2 differential pinout Pin Signal name Pin description Pin Signal name Pin description 1 AOUT0 Analog output 0 2 AOUT1 Analog output 1 3 AGND Analog ground 4 AGND A...

Страница 25: ...nput 6 9 CH1H Analog input 1 10 CH1L Analog input 5 11 CH0H Analog input 0 12 CH0L Analog input 4 13 AGND Analog ground 14 AGND Analog ground 15 D USB differential data signals 16 VBUS USB power 17 D...

Страница 26: ...ion NI Hungary Kft 10 Commerce Way H 4031 Debrecen H tar t 1 A Hungary Norton Massachusetts 02766 Phone 36 52 515400 508 946 5100 Fax 36 52 515414 Fax 508 946 9500 http hungary ni com debrecen E mail...