38
MC Technologies GmbH
Status
Connection Type
Flow Control
Server Port (default
1.9.7
ComSERVER (Only for MC Router with RS232 or RS485 interface on X1)
For remote access to terminal equipment with a serial interface, a virtual COM port connection can
additionally be established over long distances as a standard function of the router. MC
Technologies MC-Mx routers are optionally equipped with an RS232 or
RS485 interface at X1 for this purpose. For detailed information, please refer to the MC-Technologies Application Note
41 Router - COM-Port connection via MC router - RS232 / RS485.
Disable:
The ComServer is deactivated
Enable:
The ComServer is activated
Server RAW
- usage without RFC2217 Client Server Protocol
Server RFC2217 - usage with RFC2217 Client Server Protocol
S
etting the TCP port through which the ComServer is to be addressed.
Setting flow control
RFC2217
- with an RS232 application
RS485 RTS
- with an RS485 application
Note: RFC2217 is a Standard Client Server Protocol used as a standard protocol when using multiple device
servers (ComServer.) The RFC2217 protocol allows for the use of various "COM
port redirector" softwares for virtual Com Port Interfaces on the PC.
1.9.8
SMTP configuration - sending emails
For sending emails, as described under 1.8.1 Input (page 32,) an email server must be configured with the support
of the SMTP protocol. Please, use the access data of your selected email account.