Installation and use
COMPUTER XP805
19
5.2 Programming machine parameters
To access this programming phase, press the
P
SET/RESET
ROGRAMMING
key when the computer is off,
and while pressing the key, switch the computer on from the ON/OFF switch:
LIVELLO
+
ON
-
P
SPEED
L/ha
ON
AUTO
L/MIN
1.4
0.6 1.0
0 0.2
2.2
3.0
2.6
1.8
AREA
5.0
4.2 4.6
3.4
SET/RESET
3.8
REGULATION
ROGRAMMING
P
After the initial test, 5 horizontal dashes will appear on the display for about 2
seconds, after which the first programmable machine parameter will appear, and at
this point you can release the
P
SET/RESET
ROGRAMMING
key.
The possible programming modes required by the XP805 Computer will be listed
below. Vary the displayed data by pressing the
+
-
keys separately and then
you can confirm it by pressing the
P
SET/RESET
ROGRAMMING
key and then going to the next parameter.
Calibration of the feed-rate
programmable range
: 30 ÷ 999 PUL/100m
step
: 1
default
: 200
Letter "C" will flash, thereby indicating the number of pulses coming from the
speed sensor for every 100 linear metres travelled by the machine.
Programming the working width
programmable range
: 1.00 ÷ 51.00 m
step
: 0.01
default
: 2.00
The "L" will flash, thereby indicating the working width expressed in metres
Programming the type of sensor used
programmable range
: P ÷ F
step
: --
default
: P
The "S" will flash, thereby indicating the type of sensor installed and used for
the calculation of L/min and L/ha, i.e. the pressure sensor (P) or flowmeter (F)
Programming the flowmeter sensor
programmable range
: 10.0 ÷ 999.9
step
: 0.1
default
: 72.0
The "i" will flash, thereby indicating the number of pulses per litre coming from
the flowmeter
1
2
LIVELLO
+
OFF
ON
-
P
SPEED
L/ha
ON
AUTO
L/MIN
1.4
0.6 1.0
0 0.2
2.2
3.0
2.6
1.8
AREA
5.0
4.2 4.6
3.4
SET/RESET
3.8
REGULATION
ROGRAMMING
P