30 

11. Technical data 

11.1 

3.5” Virtual Terminal 

Power supply voltage 

: 10 ÷ 32 Vdc 

Maximum energy consumption 

: 150 mA 

Operating features 

Protection rating 

: IP65 

Mechanical vibrations resistance 

: 2G  

Operating conditions 

Room temperature 

: -20°C - 70°C 

Weather conditions 

: Relative humidity 80% 

Transport and storage 

Temperature 

: -25°C ÷ 70°C 

 
 

11.2 

ECU GLM 

 

Power supply voltage 

: 12 Vdc 

Absorbed current in stand-by 

: < 200 uA 

Maximum energy consumption  

:  2 A  

Operating temperature 

: -20°C ÷ 70°C    80% 

Protection rating 

: IP65 

Digital inputs 

: 6 for frequency inputs for sensor losses 
  1 for NPN max 500 Hz (type 1) 
  3 for NPN max 3 kHz (type 2) 

Output  

: 3 for frequency outputs for sensor losses 

Communication line 

: 1 x CAN BUS 2.0B (500 kbit/s) 

 

 

Содержание GLM KIT

Страница 1: ...INSTRUCTIONS FOR USE NO 1713 GLM OEM EN REV 3 EN O E M VERSION MANUFACTURERS GLM KIT GRAIN LOSSES MONITOR MONITORING SYSTEM FOR COMBINE HARVESTERS sieve sensors straw walker sensors recovery sensors...

Страница 2: ...9 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code 1713GLM OEM EN Issued April 2019 Edition November 2020 MC Elettronica S r l is not obliged to...

Страница 3: ...or sensitivity 14 3 4 Graphic interface description 15 3 4 1 Home screen 15 3 5 Work screen 16 3 6 Screen of sensor sensitivity 17 4 Programming 18 5 User settings 19 5 1 Speed sensor calibration 21 6...

Страница 4: ...ly use the equipment After buying the Monitor read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations Keep t...

Страница 5: ...nts lightning floods fire or other causes which do not depend on MC elettronica Repairs under warranty which must be carried out in the laboratories of our authorised centres are entirely free of char...

Страница 6: ...allow the operator to adjust the sieves with precision By means of a graphical interface with histograms and buzzer it will inform the operator when losses exceed the set loss threshold in order to ac...

Страница 7: ...Instructions for use GLM KIT 7 3 System installation Figure 2 3 5 Virtual Terminal dimensions 40MON 0001...

Страница 8: ...Instructions for use GLM KIT 8 Figure 3 ECU GLM dimensions code 40CEN 0001...

Страница 9: ...ear part of the Virtual Terminal using the supplied screws Fasten the suction bracket onto a clean flat surface Otherwise the Virtual Terminal can detach itself and fall during operations Note we reco...

Страница 10: ...wheel front or rear wheel of the agricultural vehicle machine or applying a metal reference protruding by at least 7 mm Figure 5 ref C Adjust the distance between the sensor and the bolts to 2 3 mm F...

Страница 11: ...by at least 7mm The distance between the sensor and its metal reference varies from 2 to 3mm The figures below show two different installation examples Figure 6 Installation of the inductive sensor D...

Страница 12: ...8 When switched on during the initial phase the following screen appears showing the software version of the Virtual Terminal 1 VT SET pressing the menu key when the system is starting up displays th...

Страница 13: ...orking cycle The following elements can be seen on the panel 1 ON OFF system switch on and switch off 2 Menu press it once to go to the next screen press and hold down to switch to the programming mod...

Страница 14: ...e 10 1 ON OFF system switch on and switch off 2 Menu press it once to go to the next screen press and hold down to switch to the programming mode 3 UP increases the selected value 4 DOWN decreases the...

Страница 15: ...f measurement selection of the type of unit of measurement to use 3 Date and time set date and hour of the system 4 Backlight display backlighting intensity adjustment 5 Buzzer volume buzzer volume ad...

Страница 16: ...RPM value of the destemmer paddle if the sensor is present 5 Counter ha h Indicates the average of the hectares worked per hour if the sensor is present 6 Variable range This area allows you to displ...

Страница 17: ...r paddle if the sensor is present 5 Counter ha h Indicates the average of the hectares worked per hour 6 Variable range This area allows you to display one of the parameters indicated below depending...

Страница 18: ...d out 2 Machine settings the screens contained in this sub menu are protected by a password that must be entered on a screen that appears when said screens open Once the password has been entered corr...

Страница 19: ...nce speed sensor is required 2 Pulses rev fan allows you to set the number of pulses rev relative to the fan sensor Set to OFF if the sensor is not present 3 Pulses rev hitter allows you to set the nu...

Страница 20: ...ble to access the sensor auto calibration described in detail below Pressing the UP key when no parameter is selected allows you to view the screen 2 Working width allows you to set the width relative...

Страница 21: ...ground at a distance of 100 metres from each other 2 Take the tractor to the previously marked first reference point and press the ENTER key to start measuring 3 Move forwards with the tractor to the...

Страница 22: ...the number starting from the digit all the way on the left and confirming the desired value with the ENTER key The procedure must be repeated for the 4 digits that make up the password Pressing the EN...

Страница 23: ...sitivity that can be set by the user 2 Straw walker constant allows you to set the straw walker sensors full scale to limit the sensitivity that can be set by the user 3 Return constant allows you to...

Страница 24: ...bility of the sieves sensors 2 Straw walker Constant allows you to set the calculation stability of the straw walker sensors 3 Return Constant allows you to set the calculation stability of the recove...

Страница 25: ...Instructions for use GLM KIT 25 7 Diagnostics Figure 20 1 ECU software version display of the ECU GLM software release 2 ECU voltage determines the voltage of the GLM control unit...

Страница 26: ...eves mult coeff 1 100 1 50 Straw walker mult coeff 1 100 1 50 Recovery mult coeff 1 100 1 50 Type of calculation time distance time Fan rev pulses ppr 0 0 20 0 0 1 1 0 Destemmer paddle rev pulses ppr...

Страница 27: ...SD for 3 5 2GB of maximum capacity Not HC not XC Formatted FAT16 not FAT32 Figure 21 2 Then insert the SD card into the housing on the left of the VT until you hear click At this point make sure that...

Страница 28: ...RAPH_35 NOR wait for the loading bar to become completely yellow and the coloured bars on the side of the display will turn off ENTER you load the Eeprom setting file file SL35_VT eep wait for the loa...

Страница 29: ...th the Virtual Terminal on we should be able to access the diagnostics menu as shown earlier and insert the SD card in the slot Then select Software Update to display a screen as shown in the figure 2...

Страница 30: ...70 C Weather conditions Relative humidity 80 Transport and storage Temperature 25 C 70 C 11 2 ECU GLM Power supply voltage 12 Vdc Absorbed current in stand by 200 uA Maximum energy consumption 2 A Ope...

Страница 31: ...5 mm Protection rating IP 67 11 3 3 Sieves straw walker recovery sensors Power supply voltage 12 Vdc Current absorption at rest 50 mA Output signal NPN 100mA Sensitivity adjustment input 1 kHz 8 Vpp D...

Страница 32: ...Instructions for use GLM KIT 32 CAUTION DO NOT WASH USING A POWER WASHER WITH PRESSURE JET...

Страница 33: ...Instructions for use 33 GLM KIT...

Страница 34: ...Printed in Italy...

Страница 35: ...Instructions for use 35 GLM KIT...

Страница 36: ...Printed in Italy www mcelettronica it Electronic equipment for agriculture...

Отзывы: