background image

 
 

Installation and use 

                                                                                     

17

 

MCK 3000 

 

5. Setting the work parameters 

5.1 Setting the working width 

Set the total working width 

“M”

 by turning the instrument on (

 key) and pressing 

the 

 key several times until the first arrow on the left on the display lights up. 

 

Settable range 

0.10 

 40.00

 

step 

0.01

 

default 

: 5.00 

 

Press 

 and 

 to change the parameter. 

Once the desired value has been reached, release the keys and wait <3> seconds to 
allow the new parameter that has just been entered to be saved. 
 
 

5.2 Setting the calibration of the feed-rate 

Set the calibration of the feed-rate 

“C”

 (number of pulses coming from the speed 

sensor every 100 metres covered by the machine), by turning the instrument on 

(

 key) and pressing the 

 key several times until the second arrow on the 

left on the display lights up.  

 

Settable range 

: 50 

 999 

step 

: 1 

default 

: 200 

 

Press 

 and 

 to change the parameter. 

Once the desired value has been reached, release the keys and wait <3> seconds to 
allow the new parameter that has just been entered to be saved. 

N.B.

  it  is  recommended  to  calibrate  this  parameter  automatically  (see  paragraph 

3.2.1.1

“Automatic calibration of parameter C””). 

 

Содержание AREA CONTROL MCK 3000

Страница 1: ...AREA CONTROL MCK 3000 UNIVERSAL HECTARE COUNTER FOR AGRICULTURAL MACHINERY USE AND ASSEMBLY INSTRUCTIONS NO 201211MI REV 2 EN...

Страница 2: ...ALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code 201211MI Issued July 2012 Edition November 2020 MC elettronica S r l is not obliged...

Страница 3: ...6 4 Accessories 16 4 1 Standard accessories 16 5 Setting the work parameters 17 5 1 Setting the working width 17 5 2 Setting the calibration of the feed rate 17 5 3 Setting the number of divisions of...

Страница 4: ...ng the Monitor read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations The manual must be kept on the machin...

Страница 5: ...e majeure events lightning floods fire or other causes which do not depend on MC elettronica Repairs under warranty which must be carried out in the laboratories of our authorised centres are entirely...

Страница 6: ...ial worked area total worked area distance travelled speed Km h forecast of the hectares that will be worked in an hour only visible while you are working The Monitor uses a speed sensor to carry out...

Страница 7: ...Installation and use 7 MCK 3000 3 System installation Figure 2 Overall dimensions...

Страница 8: ...he bracket Figure 33 ref A and by means of two screws not supplied securely fasten the bracket to the structure fasten the Monitor to the bracket by screwing the supplied knobs Figure 33 ref B in the...

Страница 9: ...rear of the agricultural machine vehicle or by creating a metal reference protruding by at least 7 mm Figure 4 ref B2 We recommend installing the speed sensor inside the wheel and placing the sensor...

Страница 10: ...ts up as shown in the figure press keys and simultaneously 0 0 will appear on the Monitor cover 100 metres and the display will show the pulse count 1 2 3 etc once the 100 metres are covered confirm w...

Страница 11: ...point of the switch by changing the number of links in the chain Figure 5 Installing the sensor in the lower part of the bar If necessary the switch can also be secured to the upper part of the bar by...

Страница 12: ...the seed sensor in a stable way on the right or left side of the pipe using the bracket supplied with the lens facing the ground and the optical axis perpendicular to the ground at a distance of no m...

Страница 13: ...trimmer A is turned to the extreme hourly position 2 Turn the monitor on The RED LED B must be on otherwise enhance the orientation or move the seed sensor closer 3 Turn the trimmer A very slowly cloc...

Страница 14: ...the data relating to the working cycle The following elements can be seen on the panel REF DESCRIPTION A ON OFF key B LCD Display C Programming key D and keys E Forward speed forecast of workable hect...

Страница 15: ...s you to set the parameter selected at that moment using the and keys by the indicator arrow total work width calibration of the feed rate number of sectors in which to split the bar Display key allow...

Страница 16: ...ys the required parameters by the keys 3 Indicator arrows indicate the function selected for every key and 4 Accessories 4 1 Standard accessories Table 4 1 Standard accessories CODE DESCRIPTION PF0481...

Страница 17: ...ntered to be saved 5 2 Setting the calibration of the feed rate Set the calibration of the feed rate C number of pulses coming from the speed sensor every 100 metres covered by the machine by turning...

Страница 18: ...ount mode by turning the instrument on key and simultaneously pressing the and keys until parameter Ct appears on the display followed by a message indicating when the monitor will count the area The...

Страница 19: ...ATA PROGRAMMING Current year Settable range 00 99 step 1 default 00 Press to confirm the data Current month Settable range 01 12 step 1 default 01 Press to confirm the data Current day Settable range...

Страница 20: ...chanical counting sensor functions Check the operation of the mechanical sensor as follows 1 Turn the monitor on key 2 Select the partial total hectare display key 3 Pull the sensor chain so as to clo...

Страница 21: ...idth By pressing the key again the Monitor also eliminates the second sector and continues to count the area with only 1 3 of the working width By pressing the key again the Monitor restores the total...

Страница 22: ...he relative key must be kept pressed for more than 3 seconds and only with the machine stopped NOTE the totalisers are all independent of each other and therefore can be zeroed independently from each...

Страница 23: ...instrument Clean the instrument with a wet cloth and mild detergent to avoid erasing the serigraphs on the panel Warning Do not use pressurised water jets Do not use abrasive products or solvents Do...

Страница 24: ...cable is disconnected a Check the power cable SENSORS The speed sensor does not work a Broken cable b Calibration distance too long c Red part of sensor damaged a Restore connection b Adjust the cali...

Страница 25: ...chanical vibrations resistance 2 G Operating conditions Room temperature 20 C 75 C Weather conditions Relative humidity 90 Transport and storage Temperature 25 C 85 C 9 2 Accessory technical data 9 2...

Страница 26: ...MCK 3000 Installation and use MCK 3000 NOTES...

Страница 27: ...Installation and use 27 MCK 3000...

Страница 28: ...MCK 3000 Installation and use MCK 3000 Electronic equipment for agriculture earthmoving industry www mcelettronica it...

Отзывы: